MACHINE_NO
stringclasses
48 values
ERROR_ID
int64
1
999
ERROR_CODE
stringclasses
245 values
ERROR_DESC
stringlengths
14
179
ERROR_CATEGORY1
stringclasses
11 values
SOLUTION
stringlengths
40
290
KM-ASSYH1-06
19
M7018
Front stage PLC1-M7018-Please press the reset button before starting the automatic process
Abnormal personnel operation
The solution for the Front stage PLC1-M7018 error described as "Please press the reset button before starting the automatic process" is as follows: Press the reset button before starting the automatic process. This process should restart and run
KM-ASSYH1-06
180
M7019
Post-stage PLC2-M7019-the equipment has not returned to the origin, please perform the equipment return to the origin first
Abnormal personnel operation
The solution to the error "Post-stage PLC2-M7019-the equipment has not returned to the origin, please perform the equipment return to the origin first" involves performing an equipment return to the origin first. This ensures
KM-ASSYH1-06
1
M7000
The front-end PLC1-M7000-starts to detect that there is material in the work area, please confirm the status of the work area
Abnormal personnel operation
Unfortunately, without any context or additional information provided, it's impossible to provide a specific solution to the described error. However, it is recommended to check the documentation and user manuals for the PLC1-M7000, as
KM-ASSYH1-06
17
M7016
If the front section PLC1-M7016-EMO&&DOOR is opened, please check the safety door or emergency stop X17
Abnormal personnel operation
The solution for this error is to check the safety door or emergency stop X17 when the front section PLC1-M7016-EMO&&DOOR is opened.
KM-ASSYH1-06
18
M7017
Front stage PLC1-M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
The solution for the abnormal Front stage PLC1-M7017 equipment model setting is to set a new, valid model in the PLC. This can usually be done through the PLC's programming software or by physically reset
KM-ASSYH1-06
20
M7019
Previous PLC1-M7019-The equipment has not returned to the origin, please perform the equipment return to the origin first
Abnormal personnel operation
The solution to the error "Previous PLC1-M7019-The equipment has not returned to the origin, please perform the equipment return to the origin first" is to first perform the equipment return to the origin before proceeding with
KM-ASSYH1-06
291
M7130
Rear section PLC2-M7130-Please remove the TRAY plate from the conveyor belt first
Abnormal personnel operation
One possible solution for this error is to physically remove the TRAY plate from the conveyor belt before the PLC2-M7130 can be accessed. This should prevent any interference or damage to the belt caused by the plate's
KM-ASSYH1-06
177
M7016
When the rear section PLC2-M7016-EMO&&DOOR is opened, please check the safety door or emergency stop X17
Abnormal personnel operation
The solution for the error you described is to ensure that the safety door or emergency stop X17 is functioning properly and has not been triggered when the PLC2-M7016-EMO&&DOOR section is opened. This
KM-ASSYH1-07
182
M7021
[Later Section] M7021-Product abnormality when starting secondary positioning
Abnormal personnel operation
The solution to the error described in M7021-Product abnormality when starting secondary positioning is to ensure that the product is positioned correctly and not obstructed. Additionally, the operator should verify that all safety features are functioning properly
KM-ASSYH1-07
189
M7028
[Later section] M7028-Safety door opens abnormally during return to origin
Abnormal personnel operation
The solution for the error described as M7028-Safety door opens abnormally during return to origin requires an inspection of the safety door drive system for any damage or malfunction. The door may need to be adjusted or replaced
KM-ASSYH1-07
195
M7034
[Later Section] M7034-Abnormal conveyor belt card in work area
Organizational Abnormality
The solution for the error described as M7034-Abnormal conveyor belt card in work area depends on the specific cause of the problem. It could be that the card is damaged or dirty, or that there is a malfunction in
KM-ASSYH1-07
198
M7037
[Later section] M7037-Work area blocking cylinder abnormality
Machine cylinder abnormality
The solution for the M7037 work area blocking cylinder abnormality error involves locating and correcting the issue that is preventing a cylinder from functioning properly in the work area. This may include adjusting the parameters of the cyl
KM-ASSYH1-07
200
M7039
[Rear section] M7039-Abnormal positioning cylinder on the side of the work area
Machine cylinder abnormality
The solution to the Rear section M7039-Abnormal positioning cylinder on the side of the work area error is to adjust or reposition the cylinder so that it is properly aligned with the work area. This may involve
KM-ASSYH1-07
203
M7042
[Rear section] M7042-Width adjustment motor rear limit abnormality
Electronic control abnormality
The solution for the "Rear section M7042-Width adjustment motor rear limit abnormality" error typically involves adjusting the width of the rear section to ensure proper clearance between the vehicle body and the rear wheels. This
KM-ASSYH1-07
209
M7048
[Rear section] M7048-Left suction nozzle lift cylinder abnormality
Machine cylinder abnormality
The solution for the error described as "rear section M7048-Left suction nozzle lift cylinder abnormality" involves checking for leaks, damage, or worn parts in the lift cylinder and replacing or repair
KM-ASSYH1-07
211
M7050
[Rear section] M7050-Left lifting cylinder abnormality
Machine cylinder abnormality
The solution for the left lifting cylinder abnormality in the rear section of M7050 is to inspect the cylinder for leaks, damage, or incorrect pressure settings. Replacement of the cylinder might be necessary if it is
KM-ASSYH1-07
213
M7052
[Rear section] M7052-Right suction nozzle lifting cylinder abnormality
Machine cylinder abnormality
The solution for the M7052 error may involve troubleshooting and repairing the right suction nozzle lifting cylinder. It may involve checking for any leaks or blockages in the nozzle that could be causing
KM-ASSYH1-07
214
M7053
[Later section]M7053-
Machine cylinder abnormality
The solution to M7053 error depends on the specific issue. It could be caused by software updates, hardware failure, or network issues. You can try updating the software or replacing the hardware, and if that doesn't work, contact
KM-ASSYH1-07
215
M7054
[Rear section] M7054-Right lifting cylinder abnormality
Machine cylinder abnormality
The solution for the error described as [Rear section] M7054-Right lifting cylinder abnormality may vary depending on the specific issue but usually involves checking the connections, pressure release valves, and replacing faulty parts.
KM-ASSYH1-07
218
M7057
[Rear section] M7057-The left suction nozzle is abnormal in vacuum suction
Electronic control abnormality
M7057 error in vacuum suction indicates abnormal behavior in the left suction nozzle of the rear section. To fix the error, inspect and clean or replace the nozzle as required.
KM-ASSYH1-07
219
M7058
[Rear section] M7058-Right suction nozzle vacuum abnormality
Electronic control abnormality
The solution for the error described as "Rear section" M7058-Right suction nozzle vacuum abnormality may involve checking for blockages or restrictions in the suction hose, inspecting the nozzle for
KM-ASSYH1-07
225
M7064
[Rear section] M7064-The upper jacking cylinder in the Tray area is abnormal
Machine cylinder abnormality
The solution for the error "Rear section M7064-The upper jacking cylinder in the Tray area is abnormal" would be to identify the cause of the abnormal condition and take corrective actions to repair or replace
KM-ASSYH1-07
227
M7066
[Rear section] M7066-The jacking cylinder at the lower level of the Tray area is abnormal
Machine cylinder abnormality
The solution for this error can vary depending on the specific details of the problem. However, one possibility could be to check if the cylinder oil is properly changed and if the jacking system is functioning optimally. If the issue is related to the
KM-ASSYH1-07
229
M7068
[Later section] M7068-The material cylinder entering the Tray section is abnormal
Machine cylinder abnormality
The solution for the error M7068 could be identifying and addressing the issue with the material cylinder, ensuring it meets the required specifications and is properly aligned with the Tray section. It may also involve updating the control software or adjust
KM-ASSYH1-06
131
M7130
Front section PLC1-M7130-Please remove the TRAY plate from the conveyor belt first
Abnormal personnel operation
The solution to the error "Front section PLC1-M7130-Please remove the TRAY plate from the conveyor belt first" is to physically remove the tray plate from the conveyor belt before attempting to process any items.
KM-ASSYH1-06
161
M7000
The back-end PLC2-M7000-starts to detect that there is material in the work area, please confirm the status of the work area
Abnormal personnel operation
The solution for the error would be to visually inspect the work area to confirm if there is any material present. Once the area is clear, the PLC can be restarted, and the error should no longer occur.
KM-ASSYH1-06
178
M7017
Backend PLC2-M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
The solution for the error "Backend PLC2-M7017-Equipment model setting is abnormal, please set the model" is to locate and reset the faulty equipment's Model Number on the Backend PLC
KM-ASSYH1-06
179
M7018
Backend PLC2-M7018-Please press the reset button before starting the automatic process
Abnormal personnel operation
The solution for the error "Backend PLC2-M7018-Please press the reset button before starting the automatic process" is to press the reset button for the PLC2-M7018 device to restart the automatic
KM-ASSYH1-07
17
M7016
[Previous section] M7016-EMO&&DOOR is open, please check the safety door or emergency stop
Abnormal personnel operation
The solution for the error "M7016-EMO&&DOOR is open, please check the safety door or emergency stop?" in a Siemens SIMATIC HMI system is usually to close the safety door or press
KM-ASSYH1-07
18
M7017
[Previous paragraph] M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
The solution for the error is to set the equipment model according to the manufacturer's instructions. This can typically be found in the documentation or on the manufacturer's website. If you are unable to find the instructions, you may need to contact the
KM-ASSYH1-07
19
M7018
[Previous paragraph] M7018-Please press the reset button before starting the automatic process
Abnormal personnel operation
The solution to this error would be to press the reset button as instructed before starting the automatic process. If the reset button doesn't work, try resetting the device or contacting customer support for further assistance.
KM-ASSYH1-07
22
M7021
[Previous paragraph] M7021-Product abnormality when starting secondary positioning
Abnormal personnel operation
The solution to M7021-Product abnormality error when starting secondary positioning may involve updating the Firmware to the latest version or manually resetting the device settings. If the problem persists, it is recommended to contact the
KM-ASSYH1-07
35
M7034
[Previous section] M7034-Abnormal conveyor belt card in work area
Organizational Abnormality
The solution for the M7034-Abnormal conveyor belt card in work area could involve several steps such as inspecting the belt for damage, clearing any debris or foreign objects, tightening the belt or replacing it if it's
KM-ASSYH1-07
38
M7037
[Front section] M7037-Work area blocking cylinder abnormality
Machine cylinder abnormality
The solution for the error described as Front section M7037-Work area blocking cylinder abnormality is to use the CNC controller's diagnostic capabilities to identify the problem and then follow the manufacturer's instructions for repair or replacement
KM-ASSYH1-07
40
M7039
[Front Section] M7039 - Abnormal positioning cylinder on the side of the work area
Machine cylinder abnormality
The solution for the M7039 error is to ensure that the positioning cylinder is in its proper location and properly secured, and to verify that all safety interlocks are functioning properly. If the issue cannot be resolved, contacting
KM-ASSYH1-07
43
M7042
[Front section] M7042-The front limit of the width adjustment motor is abnormal
Electronic control abnormality
The solution for the M7042 error is to first determine if the abnormal front limit is due to a hardware or software issue. If the issue is hardware, then it may be necessary to replace the motor or adjust its physical limits.
KM-ASSYH1-07
49
M7048
[Previous section] M7048-Left suction nozzle lifting cylinder abnormality
Machine cylinder abnormality
The solution to the error M7048-Left suction nozzle lifting cylinder abnormality involves inspecting and repairing the left suction nozzle lifting cylinder, replacing worn-out seals, checking and adjust
KM-ASSYH1-07
51
M7050
[Front Section] M7050-Left lifting cylinder abnormality
Machine cylinder abnormality
The solution for the error described as [Front Section] M7050-Left lifting cylinder abnormality involves troubleshooting, inspection, and repair of the affected components, including the lifting cylinder and any associated controls or components
KM-ASSYH1-07
53
M7052
[Previous section] M7052-Right suction nozzle lifting cylinder abnormality
Machine cylinder abnormality
The solution for the error described as M7052-Right suction nozzle lifting cylinder abnormality would involve identifying and correcting any potential issues with the lifting cylinder's wiring or connections, ensuring proper tension in
KM-ASSYH1-07
55
M7054
[Front Section] M7054-Right lifting cylinder abnormality
Machine cylinder abnormality
The solution for a front section M7054-Right lifting cylinder abnormality would involve fixing any equipment malfunctions and possibly replacing damaged components or parts to ensure proper function and performance of the affected equipment.
KM-ASSYH1-07
58
M7057
[Previous section] M7057-The left suction nozzle is abnormal in vacuum suction
Electronic control abnormality
The solution to the M7057 error often involves adjusting the suction vacuum settings and correcting any faulty hardware issues. Using the appropriate vacuum tool and removing any debris or blocks in the nozzle may also fix the issue.
KM-ASSYH1-07
59
M7058
[Previous section] M7058-Right suction nozzle is abnormal in vacuum suction
Electronic control abnormality
The solution for the error described as M7058-Right suction nozzle is abnormal in vacuum suction involves troubleshooting the nozzle to determine the cause of the problem, performing any necessary repairs, and testing
KM-ASSYH1-07
65
M7064
[Front section] M7064-The upper jacking cylinder in the Tray area is abnormal
Machine cylinder abnormality
The solution for the M7064 error in the Tray area may involve inspecting the upper jacking cylinder and addressing any abnormalities, such as replacing a faulty cylinder. The issue should be resolved as soon as possible
KM-ASSYH1-07
67
M7066
[Front section] M7066-The jacking cylinder at the lower level of the Tray area is abnormal
Machine cylinder abnormality
To resolve the error with the abnormal jacking cylinder at the lower level of the Tray area, it's recommended to check the cylinder's condition, ensure there is no leakage, lubrication of the worn parts and
KM-ASSYH1-07
69
M7068
[Previous section] M7068-The material cylinder entering the Tray section is abnormal
Machine cylinder abnormality
The solution to the error "M7068-The material cylinder entering the Tray section is abnormal?" is to address the issue by adjusting or preventing the material cylinder from entering the tray section in an abnormal manner.
KM-ASSYH1-07
161
M7000
[Later Section] M7000-Start to detect the presence of materials in the work area, please confirm the status of the work area
Abnormal personnel operation
The solution for the error described as [Later Section] M7000-Start is to confirm the status of the work area. This can be achieved by manually scanning the area using the device's sensor or by using software to
KM-ASSYH1-07
177
M7016
[Later section] M7016-EMO&&DOOR is open, please check the safety door or emergency stop
Abnormal personnel operation
The solution for this error is to check the safety door or emergency stop, close the door and retest the system. If the problem persists, maintenance or repair may be required. It is recommended to follow the manufacturer's instructions or contact a
KM-ASSYH1-07
1
M7000
[Previous section] M7000-Start to detect the presence of materials in the work area, please confirm the status of the work area
Abnormal personnel operation
The solution to the error M7000-Start to detect the presence of materials in the work area, please confirm the status of the work area is to ensure that the work area is clear and free of any materials. This will allow the
KM-ASSYH1-07
178
M7017
[Later section] M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
To resolve the error "Later section M7017-Equipment model setting is abnormal, please set the model," follow these steps: 1. Power off the device in question. 2. Reset the device to its
KM-ASSYH1-07
180
M7019
[Second paragraph] M7019-The device has not returned to the origin, please execute the device to return to the origin first
Abnormal personnel operation
The solution to the error M7019 "The device has not returned to the origin, please execute the device to return to the origin first?" is to follow the instructions provided on the device, which might include pressing a button or entering a
KM-ASSYH1-07
20
M7019
[Previous paragraph] M7019-The device has not returned to the origin, please execute the device to return to the origin first
Abnormal personnel operation
The error M7019 usually indicates that the device has not returned to the starting location. To resolve this, the device needs to be executed or instructed to return to its original location before proceeding with the task. This information is typically
KM-ASSYH1-07
29
M7028
[Previous section] M7028-EMO&&DOOR is open, please check the safety door or emergency stop
Abnormal personnel operation
The solution for the error "M7028-EMO&&DOOR is open, please check the safety door or emergency stop?" is to verify that the safety door or emergency stop is closed before operating the machine. If the safety door
KM-ASSYH2-03
19
M7018
M7018-Please press the reset button before starting the automatic process
Abnormal personnel operation
M7018 error usually occurs when the printer's automatic process fails to initiate properly. The solution is to press the reset button or perform a power cycle to restart the printer.
KM-ASSYH2-03
20
M7019
M7019-The device has not returned to the origin, please execute the device to return to the origin first
Abnormal personnel operation
The solution to the M7019 error is to first execute the device to return to its origin before attempting any further actions. This error occurs when a device is not properly synchronized with its origin, and it requires the device to be returned to
KM-ASSYH2-03
21
M7020
M7020-There is product in the left pressing area when starting
Abnormal personnel operation
The solution for the error described as M7020-"There is product in the left pressing area when starting" is to move any obstructions or product out of the left pressing area of the printer before attempting to start the print job.
KM-ASSYH2-03
22
M7021
M7021-There is a product in the middle pressing area during startup
Abnormal personnel operation
The M7021 error message indicates that there is a product in the middle pressing area during startup. To resolve the issue, remove the product from the area and check for any potential obstructions or debris that may be causing the issue. If
KM-ASSYH2-03
23
M7022
M7022-There is product on the gripper of the right flip area during startup
Abnormal personnel operation
The solution for the error M7022-There is product on the gripper of the right flip area during startup is to remove any items from the gripper and clear the work area before starting the machine.
KM-ASSYH2-03
24
M7023
M7023-There is a product on the left slide nozzle when starting, please take out the product and turn off the vacuum suction
Abnormal personnel operation
The solution for M7023 error is to remove the product from the left slide nozzle and turn off the vacuum suction.
KM-ASSYH2-03
25
M7024
M7024-There is a product on the nozzle of the middle slide table when starting, please take out the product and turn off the vacuum suction
Abnormal personnel operation
To resolve this error, follow these steps: 1. Turn off the vacuum suction and prevent any further products from entering the middle slide table nozzle. 2. Manually remove any existing product from the nozzle. 3
KM-ASSYH2-03
26
M7025
M7025-There is a product on the right nozzle when starting, please take out the product and turn off the vacuum suction
Abnormal personnel operation
M7025 is an error message indicating that there is a product on the right nozzle while starting the vacuum cleaner. To resolve this, disconnect the hose from the suction inlet and press the button to turn off
KM-ASSYH2-03
27
M7026
Kazam communication failed
Kazam exception
The solution for the "Kazam communication failed" error may vary depending on the specific cause of the issue. It could be due to an incorrect or outdated configuration, lack of permissions, or connectivity problems. Checking the Kazam server
KM-ASSYH2-03
28
M7027
M7027-The machine model has been switched, please reset the belt width adjustment first
Abnormal personnel operation
This error typically occurs when you switch between different machine models and forget to reset the belt width adjustment. To resolve the error, follow these steps: identify the correct belt width for your new machine model, and adjust the belt width accordingly. If you
KM-ASSYH2-03
29
M7028
M028-Please remove the TRAY plate from the conveyor belt first
Abnormal personnel operation
The solution to the error M028 is to follow the proper sequence of steps. This includes removing the TRAY plate from the conveyor belt before proceeding further. The system should be designed to ensure the correct order of steps are followed,
KM-ASSYH2-03
34
M7033
M7033-The discharging operation of the left working area conveyor belt has timed out, please check sensor X31
Sensor abnormality
The M7033 error indicates that the discharging operation on the left working area conveyor belt has timed out, and it requires checking sensor X31 for any failure or malfunction. To resolve this issue, you can start
KM-ASSYH2-03
33
M7032
M7032-The feeding operation of the left working area conveyor belt has timed out, please check sensor X31
Sensor abnormality
The solution for the error "M7032-The feeding operation of the left working area conveyor belt has timed out, please check sensor X31" is to investigate and repair or replace the faulty sensor X31,
KM-ASSYH2-04
11
M7010
Previous section-M7010 please confirm the status of the work area
Abnormal personnel operation
The solution to the Previous section-M7010 error is to check the work area status by checking the logs or contacting technical support for further assistance.
KM-ASSYH2-04
13
M7012
Front section-M7012-CCD compensation host computer has no response
Visual abnormality
The solution for this error varies depending on the specific problem, but generally involves troubleshooting the computer's hardware and software, verifying that all necessary drivers and firmware are up-to-date, and potentially resetting or updating the
KM-ASSYH2-04
14
M7013
Front section-M7013-No response from the upper computer in the detection process
Visual abnormality
The solution for "Front section-M7013-No response from the upper computer in the detection process" error is to check the network connection and ensure that the upper computer and the lower computer are communicating properly. Also, ensure that
KM-ASSYH2-04
15
M7014
Front section-M7014-No response from scanning QR code host computer
Visual abnormality
The solution to the Front section-M7014-No response from scanning QR code host computer error is to verify that the host computer is properly connected to the internet and that it is running the required software for scanning QR
KM-ASSYH2-04
17
M7016
M7016-EMO&&DOOR is open, please check the safety door or emergency stop
Abnormal personnel operation
The M7016-EMO&&DOOR is open error signifies that the safety door or emergency stop is open, which is unsafe. The solution is to ensure that the safety door and emergency stop are properly closed before resuming work
KM-ASSYH2-04
18
M7017
M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
The solution for the M7017-Equipment model setting is abnormal error is to check for invalid or missing values in the model settings, and to update the model accordingly. Additionally, ensure that the equipment model being used is a
KM-ASSYH2-04
19
M7018
M7018-Please press the reset button before starting the automatic process
Abnormal personnel operation
M7018 error usually occurs when the printer's automatic process fails to initiate properly. The solution is to press the reset button or perform a power cycle to restart the printer.
KM-ASSYH2-04
20
M7019
M7019-The device has not returned to the origin, please execute the device to return to the origin first
Abnormal personnel operation
The solution to the M7019 error is to first execute the device to return to its origin before attempting any further actions. This error occurs when a device is not properly synchronized with its origin, and it requires the device to be returned to
KM-ASSYH2-04
21
M7020
Previous section-M7020-Equipment reset abnormality
Electronic control abnormality
The solution for the error "Previous section-M7020-Equipment reset abnormality" would require further information and troubleshooting steps specific to the device or system experiencing the issue. Consulting technical support or referencing
KM-ASSYH2-04
22
M7021
Communication abnormality between front-end-M7021-PLC
Electronic control abnormality
Communication abnormality between front-end-M7021-PLC error typically occurs when the front-end device cannot connect to the back-end device, such as a PLC or control system. This issue can be resolved
KM-ASSYH2-04
23
M7022
Front segment-M7022-Communication abnormality between front segment and rear segment
Electronic control abnormality
The solution for the error described as Front segment-M7022-Communication abnormality between front segment and rear segment is typically to check and repair any loose connections, cables or components that may be causing the communication issue.
KM-ASSYH2-04
24
M7023
Front section-M7023-width-adjustable conveyor belt is not reset
Abnormal personnel operation
The solution for the error "Front section-M7023-width-adjustable conveyor belt is not reset" would involve resetting the conveyor belt to its default width settings. This can typically be done by accessing the settings
KM-ASSYH2-04
25
M7024
Front section-M7024-The conveyor belt product cannot return to the origin
Abnormal personnel operation
The solution for the Front section-M7024 error is to ensure the conveyor belt is properly programmed and configured to allow products to return to the origin. This can involve adjusting the control system settings, resetting the belt,
KM-ASSYH2-04
26
M7025
Front section-M7025-there is material in the waste discharge area
Abnormal personnel operation
The M7025 error indicates that there is material present in the waste discharge area of the front section of a given device. To solve this issue, the waste discharge area should be cleaned, and any obstructions or materials should be
KM-ASSYH2-04
27
M7026
Front section-M7026-return to origin or XY movement downward pressure cylinder is not above
Electronic control abnormality
The error "Front section-M7026-return to origin or XY movement downward pressure cylinder is not above" occurs when the cylinder cannot be lifted because it is not in contact with the floor. A solution can be
KM-ASSYH2-04
28
M7027
There is material in the front section-M7027-start secondary positioning platform, please take it out
Abnormal personnel operation
The solution for the error "There is material in the front section-M7027-start secondary positioning platform, please take it out" is removing or adjusting any material or debris that is blocking or impeding the secondary positioning
KM-ASSYH2-04
29
M7028
Previous segment-M7028-Buffer area Tray is lost, please restart
Abnormal personnel operation
The solution for the error "Previous segment-M7028-Buffer area Tray is lost, please restart" is to restart the printer. This error occurs when the buffer tray of the printer is full and needs to be cleared before the
KM-ASSYH2-03
1
M7000
M7000-Start detecting the presence of materials in the work area
Abnormal personnel operation
To solve the error M7000-Start detecting the presence of materials in the work area, the first step should be to check for any potential sources of contamination such as spills, debris, or dust particles. Once any materials
KM-ASSYH2-03
17
M7016
M7016-EMO&&DOOR is open, please check the safety door or emergency stop X30
Abnormal personnel operation
M7016-EMO&&DOOR is open - error message.
KM-ASSYH2-03
18
M7017
M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
The solution for the M7017-Equipment model setting is abnormal error is to check for invalid or missing values in the model settings, and to update the model accordingly. Additionally, ensure that the equipment model being used is a
KM-ASSYH2-04
33
M7032
Front section-M7032-Front buffer conveyor belt feeding operation timeout, please check sensor X23
Sensor abnormality
The solution for the error "Front section-M7032-Front buffer conveyor belt feeding operation timeout, please check sensor X23" is to check the sensor X23 for any issues or faults that may be causing the
KM-ASSYH2-04
34
M7033
Front section-M7033-the discharging operation of the front buffer conveyor belt has timed out, please check sensor X23
Sensor abnormality
The solution for Front section-M7033- timing out error is to check sensor X23 responsible for detecting the arrival of items on the front buffer conveyor belt. If the sensor is malfunctioning or obstructed,
KM-ASSYH2-04
35
M7034
Front section-M7034-Work area conveyor belt feeding operation timeout, please check sensor X24
Sensor abnormality
The solution for the Front section-M7034-Work area conveyor belt feeding operation timeout error is to check sensor X24. This could involve troubleshooting connections or calibration issues, or possibly replacing the sensor entirely.
KM-ASSYH2-04
36
M7035
Front section-M7035-The discharging operation of the conveyor belt in the work area has timed out, please check sensor X24
Sensor abnormality
The solution for this error could involve inspecting and troubleshooting sensor X24 to ensure it is functioning properly. This may involve checking its connections, replacing it if necessary, and calibrating it to ensure accurate operation. Additionally, the
KM-ASSYH2-04
37
M7036
Front section-M7036-Work area blocking cylinder is rising abnormally, please check sensor X36
Sensor abnormality
The solution for the error described as Front section-M7036-Work area blocking cylinder is rising abnormally, please check sensor X36, is likely to involve inspecting the sensor for faults or damaged wiring and
KM-ASSYH2-04
38
M7037
Front section-M7037-Work area blocking cylinder is abnormally descending, please check sensor X37
Sensor abnormality
The solution for the error "Front section-M7037-Work area blocking cylinder is abnormally descending, please check sensor X37" is to verify the functionality of the X37 sensor and ensure that it is
KM-ASSYH2-04
39
M7038
Front section-M7038-the working area side positioning cylinder extends abnormally, please check sensor X40
Sensor abnormality
The solution for the error M7038 is to check the sensor X40. If the sensor is damaged or faulty, you may need to replace it. If the sensor is in good condition, then there may be a problem with
KM-ASSYH2-04
40
M7039
Front section-M7039-the working area side positioning cylinder retracts abnormally, please check sensor X41
Sensor abnormality
The solution for the error Front section-M7039-the working area side positioning cylinder retracts abnormally, please check sensor X41, is to inspect the sensor X41 for any faults or mal
KM-ASSYH2-04
41
M7040
Front section-M7040-upper cover side positioning cylinder (front), abnormal extension, please check sensor X43
Sensor abnormality
The solution for the "Front section-M7040-upper cover side positioning cylinder (front), abnormal extension, please check sensor X43" error, which is related to the extension of the front positioning cylinder
KM-ASSYH2-04
42
M7041
Front section-M7041-upper cover side positioning cylinder (front), retraction abnormality, please check sensor X44
Sensor abnormality
The solution for the error described as Front section-M7041-upper cover side positioning cylinder (front), retraction abnormality, please check sensor X44 involves checking the position of the upper cover side positioning cyl
KM-ASSYH2-04
44
M7043
Front section-M7043-upper cover front positioning cylinder-retract (front), retraction is abnormal, please check sensor X46
Sensor abnormality
The solution for the error "Front section-M7043-upper cover front positioning cylinder-retract (front), retraction is abnormal, please check sensor X46" involves checking sensor X46 to ensure that
KM-ASSYH2-04
45
M7044
Front section-M7044-Push PCB cylinder-extend (front), the extension is abnormal, please check sensor X47
Sensor abnormality
The solution for the error Front section-M7044-Push PCB cylinder-extend (front), abnormal extension, and checking sensor X47 involves physically inspecting and possibly replacing the sensor X47. It may also
KM-ASSYH2-04
46
M7045
Front section-M7045-push PCB cylinder-retract (front), retraction is abnormal, please check sensor X50
Sensor abnormality
The error "Front section-M7045-push PCB cylinder-retract (front), retraction is abnormal, please check sensor X50" describes a problem with a push button PCB cylinder in the computer
KM-ASSYH2-04
48
M7047
Front section - M7047 - tilting cylinder - lowering (front), retraction is abnormal, please check sensor X52
Sensor abnormality
The solution to the error described as Front section - M7047 - tilting cylinder - lowering (front), retraction is abnormal, please check sensor X52 is to ensure the sensor is calibrated and functioning properly
KM-ASSYH2-04
49
M7048
Front section-M7048-upper cover side positioning cylinder (middle), abnormal extension, please check sensor X54
Sensor abnormality
The solution for the Front section-M7048-upper cover side positioning cylinder (middle), abnormal extension, please check sensor X54 error is to repair or replace the faulty sensor (X54) and reset