MACHINE_NO
stringclasses 48
values | ERROR_ID
int64 1
999
| ERROR_CODE
stringclasses 245
values | ERROR_DESC
stringlengths 14
179
| ERROR_CATEGORY1
stringclasses 11
values | SOLUTION
stringlengths 40
290
|
---|---|---|---|---|---|
KM-ASSYH2-05 | 29 | M7028 | The communication enable between the front-end PLC1-M7028-PLC1 and PLC2 is abnormal, please check the communication line | Electronic control abnormality | The solution for the communication enable error between the front-end PLC1-M7028-PLC1 and PLC2 is to check the communication line for any potential issues such as physical damage or electromagnetic interference. It |
KM-ASSYH2-05 | 30 | M7029 | Front section PLC1-M7029-the cylinder is not in the safe position when returning to the origin, please reset the cylinder first | Abnormal personnel operation | The solution for the error described in the question is to reset the cylinder first before returning to the origin, which will put the cylinder back in the safe position. This step is necessary to ensure that the cylinder is properly secured before it can |
KM-ASSYH2-05 | 31 | M7030 | Front section PLC1-M7030-There is material on the material throwing platform, please take it away first | Abnormal personnel operation | The error message "Front section PLC1-M7030: There is material on the material throwing platform, please take it away first?" usually indicates that a layer of material is jamming the platform of a material handling system. The |
KM-ASSYH2-05 | 32 | M7031 | Front stage PLC1-M7031-after switching the model, please perform a width adjustment reset first | Abnormal personnel operation | The solution to the error "Front stage PLC1-M7031-after switching the model, please perform a width adjustment reset first" is to perform a width adjustment reset before proceeding with the new PLC model. |
KM-ASSYH2-05 | 33 | M7032 | Front section PLC1-M7032-the front buffer conveyor belt feeding operation timeout, please check sensor X50 | Sensor abnormality | To solve the Front section PLC1-M7032 error, you should first check the sensor X50 to ensure it is properly functioning. If the sensor is found to be faulty, then replace it or troubleshoot the |
KM-ASSYH2-04 | 229 | M7068 | Rear section-M7068-the rear suction nozzle presses down the cylinder-liter, and the extension is abnormal, please check the sensor X34 | Sensor abnormality | The solution to the error with Rear section-M7068-the rear suction nozzle presses down on the cylinder-liter, and the extension is abnormal may involve checking sensor X34. |
KM-ASSYH2-04 | 43 | M7042 | Front section - M7042 - upper cover front positioning cylinder - extension (front), extension is abnormal, please check sensor X45 | Sensor abnormality | The solution for the error described as Front section - M7042 - upper cover front positioning cylinder - extension (front), extension is abnormal, please check sensor X45, is to inspect sensor X45 for proper function |
KM-ASSYH2-04 | 204 | M7043 | Rear section-M7043-upper cover front positioning cylinder-retract (front), retraction is abnormal, please check sensor X46 | Sensor abnormality | The solution for the error described as Rear section-M7043-upper cover front positioning cylinder-retract (front), retraction is abnormal, please check sensor X46 involves repair or replacement of the M7 |
KM-ASSYH2-04 | 47 | M7046 | Front section-M7046-tilt cylinder-liter (front), abnormal extension, please check sensor X51 | Sensor abnormality | The solution for abnormal extension in front section-M7046-tilt cylinder-liter due to sensor X51 malfunction may require the replacement or calibration of the sensor, as well as inspecting the cylinder shaft |
KM-ASSYH2-04 | 208 | M7047 | Rear section - M7047 - tilting cylinder - lowering (front), retraction is abnormal, please check sensor X52 | Sensor abnormality | The solution to the error described as Rear section - M7047 - tilting cylinder - lowering (front), retraction is abnormal, please check sensor X52 involves checking the sensor X52 to ensure it is |
KM-ASSYH2-04 | 211 | M7050 | Rear section-M7050-upper cover front positioning cylinder-extension (middle), extension is abnormal, please check sensor X56 | Sensor abnormality | The solution for the described error on M7050 machine with abnormal rear section extension likely involves fixing or replacing faulty sensor X56. |
KM-ASSYH2-04 | 54 | M7053 | Front section-M7053-push PCB cylinder-retract (middle), retraction is abnormal, please check sensor X61 | Sensor abnormality | The M7053-push PCB cylinder-retract error can be resolved by checking sensor X61. This sensor detects the position of the PCB cylinder and could be faulty if it is not functioning correctly. |
KM-ASSYH2-04 | 215 | M7054 | Rear section-M7054-tilt cylinder-rising (middle), abnormal extension, please check sensor X62 | Sensor abnormality | The solution for the error described as Rear section-M7054-tilt cylinder-rising (middle), abnormal extension, please check sensor X62 is to reset the sensor X62 and check its connection. |
KM-ASSYH2-04 | 58 | M7057 | Front section-M7057-upper cover side positioning cylinder (rear), retraction abnormality, please check sensor X66 | Sensor abnormality | The solution for the described error of the M7057 positioning cylinder abnormality with sensor X66 may require checking the sensor for proper functioning, calibration, or replacement. Additionally, reviewing the control logic and hardware components |
KM-ASSYH2-04 | 50 | M7049 | Front section-M7049-upper cover side positioning cylinder (middle), retraction abnormality, please check sensor X55 | Sensor abnormality | The solution for the error described as Front section-M7049-upper cover side positioning cylinder (middle), retraction abnormality, please check sensor X55 is to inspect and potentially replace sensor X55. This |
KM-ASSYH2-04 | 61 | M7060 | Front section - M7060 - push PCB cylinder - extension (rear), extension is abnormal, please check sensor X71 | Sensor abnormality | The solution for the error "Front section - M7060 - push PCB cylinder - extension (rear), extension is abnormal, please check sensor X71" involves inspecting and possibly replacing the sensor X71 to |
KM-ASSYH2-05 | 34 | M7033 | Front section PLC1-M7033-the discharging operation of the front buffer conveyor belt has timed out, please check sensor X50 | Sensor abnormality | The solution to this error is to check the sensor X50 to ensure it is functioning correctly. If the sensor is causing the failure of the discharging operation, then it may need to be adjusted or replaced. |
KM-ASSYH2-05 | 35 | M7034 | Front section PLC1-M7034-The feeding operation of the conveyor belt in the work area has timed out, please check sensor X51 | Sensor abnormality | The solution for the described error is to reset the conveyor belt and check the sensor X51. If the sensor is not functioning properly, it should be replaced or repaired to allow the conveyor belt to resume its feeding operation. |
KM-ASSYH2-05 | 36 | M7035 | Front section PLC1-M7035-work area conveyor belt discharging operation timeout, please check sensor X51 | Sensor abnormality | The solution for the Front section PLC1-M7035-work area conveyor belt discharging operation timeout error may involve checking sensor X51 to ensure it is functioning properly or may require additional troubleshooting steps to |
KM-ASSYH2-05 | 37 | M7036 | Front section PLC1-M7036-the working area blocking cylinder is rising abnormally, please check sensor X52 | Sensor abnormality | The solution for the described error on Front section PLC1-M7036 may involve checking sensor X52, which likely detects the position of the working area blocking cylinder. The sensor could be faulty or misconfigured |
KM-ASSYH2-05 | 38 | M7037 | Front section PLC1-M7037-the work area blocking cylinder is descending abnormally, please check sensor X53 | Sensor abnormality | The solution for the error described could potentially involve checking sensor X53 to ensure that it is functioning properly, or it could require checking wiring connections and making any necessary repairs to the descending abnormally blocking cylinder in the front section of |
KM-ASSYH2-05 | 39 | M7038 | Front section PLC1-M7038-the working area side positioning cylinder protrudes abnormally, please check sensor X54 | Sensor abnormality | The error message indicates that the working area side positioning cylinder protrudes abnormally. The possible solution could involve checking the sensor X54 to ensure that it is functioning correctly. If the sensor is malfunctioning, it may need |
KM-ASSYH2-05 | 49 | M7048 | Front section PLC1-M7048-the picking clamp is rising abnormally, please check the sensor-X60 | Sensor abnormality | The solution for the error described as Front section PLC1-M7048-the picking clamp is rising abnormally, please check the sensor-X60 is to inspect and maintain the sensor X60 to ensure it |
KM-ASSYH2-05 | 50 | M7049 | Front section PLC1-M7049-the picking clamp has dropped abnormally, please check the sensor-X61 | Sensor abnormality | The error message "Front section PLC1-M7049-the picking clamp has dropped abnormally, please check the sensor-X61" refers to a specific type of error that may occur in a machine control system |
KM-ASSYH2-05 | 51 | M7050 | Front section PLC1-M7050-the discharge clamp claw rises abnormally, please check the sensor-X62 | Sensor abnormality | The solution for the error "Front section PLC1-M7050-the discharge clamp claw rises abnormally, please check the sensor-X62" could involve checking the X62 sensor's |
KM-ASSYH2-05 | 52 | M7051 | Front section PLC1-M7051-the discharging clamp jaw has dropped abnormally, please check the sensor-X63 | Sensor abnormality | The solution for the error described as Front section PLC1-M7051-the discharging clamp jaw has dropped abnormally, please check the sensor-X63 is to inspect the sensor-X63 for |
KM-ASSYH2-05 | 54 | M7053 | The previous section PLC1-M7053-Product No. 1 failed to scan the code, please check whether the barcode is abnormal | Visual abnormality | The error message indicates that the barcode scanned by PLC code is abnormal and therefore did not match to the expected Product No. To resolve the issue, the barcode should be checked for errors or if it belongs to a different product, |
KM-ASSYH2-05 | 55 | M7054 | The front-end PLC1-M7054-No. 2 product failed to scan the code, please check whether the barcode is abnormal | Visual abnormality | The solution for the error is to check whether the barcode is abnormal or damaged. If the barcode is fine, it could be possible that there is a problem with the scanner or the software used for scanning. In such cases, |
KM-ASSYH2-05 | 56 | M7055 | The front section PLC1-M7055-Product No. 3 failed to scan the code, please check whether the barcode is abnormal | Visual abnormality | The problem described is likely caused by a malfunctioning barcode reader or barcode that is abnormal. Possible solutions include a replacement or calibration of the barcode reader, testing of the barcode using a different reader or device, or |
KM-ASSYH2-05 | 58 | M7057 | The previous section PLC1-M7057-Product No. 5 failed to scan the code, please check whether the barcode is abnormal | Visual abnormality | The solution for the error "The previous section PLC1-M7057-Product No. 5 failed to scan the code, please check whether the barcode is abnormal?" can be checked by verifying if the barcode |
KM-ASSYH2-05 | 59 | M7058 | The front section PLC1-M7058-Product No. 6 failed to scan the code, please check whether the barcode is abnormal | Visual abnormality | The solution for the error could involve first checking the barcode for any abnormalities, then ensuring that the barcode laser scanner is functioning properly, and updating any necessary software or firmware on the PLC. If the problem persists, |
KM-ASSYH2-05 | 60 | M7059 | Front section PLC1-M7059-camera photo recognition failed | Visual abnormality | The error "Front section PLC1-M7059-camera photo recognition failed" indicates that the photo recognition function of the M7059 camera installed on PLC1 in the front section has failed. To resolve this issue |
KM-ASSYH2-05 | 61 | M7060 | Front stage PLC1-M7060-Pressure value reading failed, please check | Electronic control abnormality | The solution to Front stage PLC1-M7060-Pressure value reading failed error is to check if the connection between the pressure sensor and the PLC is secure and functioning correctly. Also, ensure that the PLC is powered |
KM-ASSYH2-05 | 65 | M7064 | Front section PLC1-M7064-the front positioning cylinder of the pressing area protrudes abnormally-X74 | Organizational Abnormality | The solution to the X74 error in PLC1-M7064, where the front positioning cylinder of the pressing area protrudes abnormally, may involve checking the wiring and connections to ensure proper functionality. |
KM-ASSYH2-05 | 66 | M7065 | Front section PLC1-M7065-retraction abnormality of the front positioning cylinder in the pressing area-X75 | Organizational Abnormality | The solution for the error Front section PLC1-M7065-retraction abnormality of the front positioning cylinder in the pressing area-X75 requires identifying and correcting the root cause of the problem. |
KM-ASSYH2-05 | 67 | M7066 | Front section PLC1-M7066-pressure area side positioning cylinder protrusion abnormality-X72 | Organizational Abnormality | The solution for Front section PLC1-M7066-pressure area side positioning cylinder protrusion abnormality-X72 error involves identifying the root cause of the issue, performing maintenance or repairs on the affected |
KM-ASSYH2-05 | 68 | M7067 | Front section PLC1-M7067-pressure area side positioning cylinder retraction abnormality-X73 | Organizational Abnormality | The solution for the error "Front section PLC1-M7067-pressure area side positioning cylinder retraction abnormality-X73" would depend on the specifics of the malfunction, but may involve |
KM-ASSYH2-05 | 69 | M7068 | Front section PLC1-M7068-pressure area lower pressure cylinder 1 rises abnormally-X76 | Organizational Abnormality | There are different possible causes of the described error, and the solution may depend on the specific root cause. It is recommended to consult the technical manual or contact the equipment manufacturer for more information and instructions on how to fix the issue. The basic steps may |
KM-ASSYH2-05 | 131 | M7130 | Front section PLC1-M7130-Please remove the TRAY plate from the conveyor belt first | Abnormal personnel operation | The solution to the error "Front section PLC1-M7130-Please remove the TRAY plate from the conveyor belt first" is to physically remove the tray plate from the conveyor belt before attempting to process any items. |
KM-ASSYH2-05 | 161 | M7000 | The back-end PLC2-M7000-starts to detect that there is material in the work area, please confirm the status of the work area | Abnormal personnel operation | The solution for the error would be to visually inspect the work area to confirm if there is any material present. Once the area is clear, the PLC can be restarted, and the error should no longer occur. |
KM-ASSYH2-05 | 177 | M7016 | When the rear section PLC2-M7016-EMO&&DOOR is opened, please check the safety door or emergency stop X17 | Abnormal personnel operation | The solution for the error you described is to ensure that the safety door or emergency stop X17 is functioning properly and has not been triggered when the PLC2-M7016-EMO&&DOOR section is opened. This |
KM-ASSYH2-05 | 178 | M7017 | Backend PLC2-M7017-Equipment model setting is abnormal, please set the model | Abnormal personnel operation | The solution for the error "Backend PLC2-M7017-Equipment model setting is abnormal, please set the model" is to locate and reset the faulty equipment's Model Number on the Backend PLC |
KM-ASSYH2-05 | 179 | M7018 | Backend PLC2-M7018-Please press the reset button before starting the automatic process | Abnormal personnel operation | The solution for the error "Backend PLC2-M7018-Please press the reset button before starting the automatic process" is to press the reset button for the PLC2-M7018 device to restart the automatic |
KM-ASSYH2-05 | 180 | M7019 | Post-stage PLC2-M7019-the equipment has not returned to the origin, please perform the equipment return to the origin first | Abnormal personnel operation | The solution to the error "Post-stage PLC2-M7019-the equipment has not returned to the origin, please perform the equipment return to the origin first" involves performing an equipment return to the origin first. This ensures |
KM-ASSYH2-05 | 181 | M7020 | Rear section PLC2-M7020-There is material in the pressing area, please take it away first | Abnormal personnel operation | To solve this error, you can physically remove any material present in the pressing area of PLC2-M7020. After that, restart your machine to allow it to continue functioning normally. If you still encounter the same issue after physical |
KM-ASSYH2-05 | 182 | M7021 | Post-stage PLC1-M7021-the Z-axis is not in the safe position during reset, please perform return to origin first | Abnormal personnel operation | The solution for the error PLC1-M7021 "Z-axis is not in the safe position during reset, please perform return to origin first" is to ensure that the Z-axis is in its safe position before resetting |
KM-ASSYH2-05 | 183 | M7022 | Post-stage PLC1-M7022-timed out 10S while waiting for the scan code result | Visual abnormality | The solution to the error Post-stage PLC1-M7022-timed out 10S while waiting for the scan code result, is to increase the time out duration for the scan code in the device configuration settings. |
KM-ASSYH2-05 | 184 | M7023 | Backend PLC1-M7023-timed out 10S waiting for the camera to take pictures | Visual abnormality | The solution for the error described as Backend PLC1-M7023-timed out 10S waiting for the camera to take pictures involves resetting or reinitializing the camera, checking for any software or firmware |
KM-ASSYH2-05 | 185 | M7024 | Backend PLC1-M7024-waiting for the next camera to take pictures timed out 10S | Visual abnormality | The solution for the error "Backend PLC1-M7024-waiting for the next camera to take pictures timed out 10S" could possibly involve checking if there are any conflicts with camera software or hardware, ver |
KM-ASSYH2-05 | 186 | M7025 | Backend PLC1-M7025-timeout 10S waiting for the host computer to reply to the assembly point | Machine communication abnormality | The solution for the error "Backend PLC1-M7025-timeout 10S waiting for the host computer to reply to the assembly point" is to ensure that the host computer is properly configured and accessible by the PLC |
KM-ASSYH2-05 | 187 | M7026 | Post-stage PLC1-M7026-timed out 10S while waiting for the host computer to reply to the pressing result | Machine communication abnormality | This error typically indicates that the PLC waits for more than 10 seconds for the host computer to reply to the pressing result. It may be caused by network issues or slow communication between the devices. One solution is to check the network connection |
KM-ASSYH2-05 | 188 | M7027 | Post-stage PLC1-M7027-waiting for the host computer to reply LINK result timed out 10S | Machine communication abnormality | The error "Post-stage PLC1-M7027-waiting for the host computer to reply LINK result timed out 10S" indicates that the PLC is waiting for a response from the host computer, |
KM-ASSYH2-05 | 189 | M7028 | The communication enable between the back-end PLC2-M7028-PLC1 and PLC2 is abnormal, please check the communication line | Electronic control abnormality | It's recommended to check the communication line between the back-end PLC2-M7028-PLC1 and PLC2 to ensure that there are no issues, such as cable damage or loose connections, that may be |
KM-ASSYH2-05 | 190 | M7029 | Rear section PLC2-M7029-the cylinder is not in the safe position when returning to the origin, please reset the cylinder first | Abnormal personnel operation | To resolve the error "Rear section PLC2-M7029-cylinder is not in the safe position when returning to the origin, please reset the cylinder first," you need to manually reset the cylinder to the |
KM-ASSYH2-05 | 191 | M7030 | Rear section PLC2-M7030-There is material on the material throwing platform, please take it away first | Abnormal personnel operation | The solution for the error "Rear section PLC2-M7030-There is material on the material throwing platform, please take it away first?" involves physical removal of any materials present on the material throw platform before continuing with the |
KM-ASSYH2-05 | 192 | M7031 | Backend PLC2-M7031-After switching the model, please perform a width adjustment reset first | Abnormal personnel operation | The solution to the error described as "Backend PLC2-M7031-After switching the model, please perform a width adjustment reset first" is to perform a width adjustment reset before switching the model in the PLC2 |
KM-ASSYH2-05 | 193 | M7032 | Back-end PLC2-M7032-the front buffer conveyor belt feeding operation timeout, please check sensor X50 | Sensor abnormality | The solution for the error described as Back-end PLC2-M7032-the front buffer conveyor belt feeding operation timeout, please check sensor X50, is to check the sensor X50 to ensure it is functioning |
KM-ASSYH2-05 | 194 | M7033 | Rear section PLC2-M7033-the discharging operation of the front buffer conveyor belt has timed out, please check the sensor X50 | Sensor abnormality | The solution for the error "Rear section PLC2-M7033-the discharging operation of the front buffer conveyor belt has timed out, please check the sensor X50" is to check the sensor X |
KM-ASSYH2-05 | 195 | M7034 | Rear-end PLC2-M7034-Work area conveyor belt feeding operation timeout, please check sensor X51 | Sensor abnormality | The solution to the described error requiring attention to sensor X51 on the rear-end PLC2-M7034-Work area conveyor belt feeding operation timeout is to check the condition of the sensor and verify that it is functioning |
KM-ASSYH2-05 | 196 | M7035 | Rear section PLC2-M7035-The discharging operation of the conveyor belt in the work area has timed out, please check sensor X51 | Sensor abnormality | The solution to the error described as "Rear Section PLC2-M7035-The discharging operation of the conveyor belt in the work area has timed out, please check sensor X51" is to reset |
KM-ASSYH2-05 | 40 | M7039 | Front section PLC1-M7039-the working area side positioning cylinder retracts abnormally, please check sensor X55 | Sensor abnormality | The solution for the error described as Front section PLC1-M7039-the working area side positioning cylinder retracts abnormally, please check sensor X55, would be to first check the sensor X5 |
KM-ASSYH2-05 | 53 | M7052 | The front section PLC1-M7052-vacuum is abnormal when removing the upper cover, please check whether the X57 vacuum is abnormal | Electronic control abnormality | Check the X57 vacuum relay by opening its control circuit and monitoring it for any faults, including blown fuses, missing parts, or visible damage. You should also check the vacuum level in the X57 vacuum relay by using a vacuum |
KM-ASSYH2-05 | 57 | M7056 | The front-end PLC1-M7056-No. 4 product failed to scan the code, please check whether the barcode is abnormal | Visual abnormality | The solution for this error is to check the barcode. If it is abnormal, fix it before scanning again. If the barcode is correct, check the PLC settings and ensure the barcode scanner is properly calibrated and |
KM-ASSYH2-05 | 27 | M7026 | Front-stage PLC1-M7026-timed out 10S while waiting for the host computer to reply to the pressing result | Machine communication abnormality | The Front-stage PLC1-M7026-timed out 10S error is usually caused by a communication issue between the PLC and the host computer. Possible solutions include checking the communication settings, restarting the |
KM-ASSYH2-06 | 131 | M7130 | Front section PLC1-M7130-Please remove the TRAY plate from the conveyor belt first | Abnormal personnel operation | The solution to the error "Front section PLC1-M7130-Please remove the TRAY plate from the conveyor belt first" is to physically remove the tray plate from the conveyor belt before attempting to process any items. |
KM-ASSYH2-06 | 161 | M7000 | The back-end PLC2-M7000-starts to detect that there is material in the work area, please confirm the status of the work area | Abnormal personnel operation | The solution for the error would be to visually inspect the work area to confirm if there is any material present. Once the area is clear, the PLC can be restarted, and the error should no longer occur. |
KM-ASSYH2-06 | 177 | M7016 | When the rear section PLC2-M7016-EMO&&DOOR is opened, please check the safety door or emergency stop X17 | Abnormal personnel operation | The solution for the error you described is to ensure that the safety door or emergency stop X17 is functioning properly and has not been triggered when the PLC2-M7016-EMO&&DOOR section is opened. This |
KM-ASSYH2-06 | 178 | M7017 | Backend PLC2-M7017-Equipment model setting is abnormal, please set the model | Abnormal personnel operation | The solution for the error "Backend PLC2-M7017-Equipment model setting is abnormal, please set the model" is to locate and reset the faulty equipment's Model Number on the Backend PLC |
KM-ASSYH2-06 | 179 | M7018 | Backend PLC2-M7018-Please press the reset button before starting the automatic process | Abnormal personnel operation | The solution for the error "Backend PLC2-M7018-Please press the reset button before starting the automatic process" is to press the reset button for the PLC2-M7018 device to restart the automatic |
KM-ASSYH2-06 | 180 | M7019 | Post-stage PLC2-M7019-the equipment has not returned to the origin, please perform the equipment return to the origin first | Abnormal personnel operation | The solution to the error "Post-stage PLC2-M7019-the equipment has not returned to the origin, please perform the equipment return to the origin first" involves performing an equipment return to the origin first. This ensures |
KM-ASSYH2-06 | 181 | M7020 | Rear section PLC2-M7020-There is material in the pressing area, please take it away first | Abnormal personnel operation | To solve this error, you can physically remove any material present in the pressing area of PLC2-M7020. After that, restart your machine to allow it to continue functioning normally. If you still encounter the same issue after physical |
KM-ASSYH2-06 | 182 | M7021 | Post-stage PLC1-M7021-the Z-axis is not in the safe position during reset, please perform return to origin first | Abnormal personnel operation | The solution for the error PLC1-M7021 "Z-axis is not in the safe position during reset, please perform return to origin first" is to ensure that the Z-axis is in its safe position before resetting |
KM-ASSYH2-06 | 183 | M7022 | Post-stage PLC1-M7022-timed out 10S while waiting for the scan code result | Visual abnormality | The solution to the error Post-stage PLC1-M7022-timed out 10S while waiting for the scan code result, is to increase the time out duration for the scan code in the device configuration settings. |
KM-ASSYH2-06 | 184 | M7023 | Backend PLC1-M7023-timed out 10S waiting for the camera to take pictures | Visual abnormality | The solution for the error described as Backend PLC1-M7023-timed out 10S waiting for the camera to take pictures involves resetting or reinitializing the camera, checking for any software or firmware |
KM-ASSYH2-06 | 185 | M7024 | Backend PLC1-M7024-waiting for the next camera to take pictures timed out 10S | Visual abnormality | The solution for the error "Backend PLC1-M7024-waiting for the next camera to take pictures timed out 10S" could possibly involve checking if there are any conflicts with camera software or hardware, ver |
KM-ASSYH2-06 | 186 | M7025 | Backend PLC1-M7025-timeout 10S waiting for the host computer to reply to the assembly point | Machine communication abnormality | The solution for the error "Backend PLC1-M7025-timeout 10S waiting for the host computer to reply to the assembly point" is to ensure that the host computer is properly configured and accessible by the PLC |
KM-ASSYH2-06 | 187 | M7026 | Post-stage PLC1-M7026-timed out 10S while waiting for the host computer to reply to the pressing result | Machine communication abnormality | This error typically indicates that the PLC waits for more than 10 seconds for the host computer to reply to the pressing result. It may be caused by network issues or slow communication between the devices. One solution is to check the network connection |
KM-ASSYH2-06 | 188 | M7027 | Post-stage PLC1-M7027-waiting for the host computer to reply LINK result timed out 10S | Machine communication abnormality | The error "Post-stage PLC1-M7027-waiting for the host computer to reply LINK result timed out 10S" indicates that the PLC is waiting for a response from the host computer, |
KM-ASSYH2-06 | 189 | M7028 | The communication enable between the back-end PLC2-M7028-PLC1 and PLC2 is abnormal, please check the communication line | Electronic control abnormality | It's recommended to check the communication line between the back-end PLC2-M7028-PLC1 and PLC2 to ensure that there are no issues, such as cable damage or loose connections, that may be |
KM-ASSYH2-06 | 38 | M7037 | Front section PLC1-M7037-the work area blocking cylinder is descending abnormally, please check sensor X53 | Sensor abnormality | The solution for the error described could potentially involve checking sensor X53 to ensure that it is functioning properly, or it could require checking wiring connections and making any necessary repairs to the descending abnormally blocking cylinder in the front section of |
KM-ASSYH2-06 | 39 | M7038 | Front section PLC1-M7038-the working area side positioning cylinder protrudes abnormally, please check sensor X54 | Sensor abnormality | The error message indicates that the working area side positioning cylinder protrudes abnormally. The possible solution could involve checking the sensor X54 to ensure that it is functioning correctly. If the sensor is malfunctioning, it may need |
KM-ASSYH2-06 | 40 | M7039 | Front section PLC1-M7039-the working area side positioning cylinder retracts abnormally, please check sensor X55 | Sensor abnormality | The solution for the error described as Front section PLC1-M7039-the working area side positioning cylinder retracts abnormally, please check sensor X55, would be to first check the sensor X5 |
KM-ASSYH2-06 | 49 | M7048 | Front section PLC1-M7048-the picking clamp is rising abnormally, please check the sensor-X60 | Sensor abnormality | The solution for the error described as Front section PLC1-M7048-the picking clamp is rising abnormally, please check the sensor-X60 is to inspect and maintain the sensor X60 to ensure it |
KM-ASSYH2-06 | 50 | M7049 | Front section PLC1-M7049-the picking clamp has dropped abnormally, please check the sensor-X61 | Sensor abnormality | The error message "Front section PLC1-M7049-the picking clamp has dropped abnormally, please check the sensor-X61" refers to a specific type of error that may occur in a machine control system |
KM-ASSYH2-06 | 51 | M7050 | Front section PLC1-M7050-the discharge clamp claw rises abnormally, please check the sensor-X62 | Sensor abnormality | The solution for the error "Front section PLC1-M7050-the discharge clamp claw rises abnormally, please check the sensor-X62" could involve checking the X62 sensor's |
KM-ASSYH2-06 | 52 | M7051 | Front section PLC1-M7051-the discharging clamp jaw has dropped abnormally, please check the sensor-X63 | Sensor abnormality | The solution for the error described as Front section PLC1-M7051-the discharging clamp jaw has dropped abnormally, please check the sensor-X63 is to inspect the sensor-X63 for |
KM-ASSYH2-06 | 53 | M7052 | The front section PLC1-M7052-vacuum is abnormal when removing the upper cover, please check whether the X57 vacuum is abnormal | Electronic control abnormality | Check the X57 vacuum relay by opening its control circuit and monitoring it for any faults, including blown fuses, missing parts, or visible damage. You should also check the vacuum level in the X57 vacuum relay by using a vacuum |
KM-ASSYH2-06 | 54 | M7053 | The previous section PLC1-M7053-Product No. 1 failed to scan the code, please check whether the barcode is abnormal | Visual abnormality | The error message indicates that the barcode scanned by PLC code is abnormal and therefore did not match to the expected Product No. To resolve the issue, the barcode should be checked for errors or if it belongs to a different product, |
KM-ASSYH2-06 | 56 | M7055 | The front section PLC1-M7055-Product No. 3 failed to scan the code, please check whether the barcode is abnormal | Visual abnormality | The problem described is likely caused by a malfunctioning barcode reader or barcode that is abnormal. Possible solutions include a replacement or calibration of the barcode reader, testing of the barcode using a different reader or device, or |
KM-ASSYH2-06 | 57 | M7056 | The front-end PLC1-M7056-No. 4 product failed to scan the code, please check whether the barcode is abnormal | Visual abnormality | The solution for this error is to check the barcode. If it is abnormal, fix it before scanning again. If the barcode is correct, check the PLC settings and ensure the barcode scanner is properly calibrated and |
KM-ASSYH2-06 | 58 | M7057 | The previous section PLC1-M7057-Product No. 5 failed to scan the code, please check whether the barcode is abnormal | Visual abnormality | The solution for the error "The previous section PLC1-M7057-Product No. 5 failed to scan the code, please check whether the barcode is abnormal?" can be checked by verifying if the barcode |
KM-ASSYH2-06 | 59 | M7058 | The front section PLC1-M7058-Product No. 6 failed to scan the code, please check whether the barcode is abnormal | Visual abnormality | The solution for the error could involve first checking the barcode for any abnormalities, then ensuring that the barcode laser scanner is functioning properly, and updating any necessary software or firmware on the PLC. If the problem persists, |
KM-ASSYH2-06 | 61 | M7060 | Front stage PLC1-M7060-Pressure value reading failed, please check | Electronic control abnormality | The solution to Front stage PLC1-M7060-Pressure value reading failed error is to check if the connection between the pressure sensor and the PLC is secure and functioning correctly. Also, ensure that the PLC is powered |
KM-ASSYH2-06 | 65 | M7064 | Front section PLC1-M7064-the front positioning cylinder of the pressing area protrudes abnormally-X74 | Organizational Abnormality | The solution to the X74 error in PLC1-M7064, where the front positioning cylinder of the pressing area protrudes abnormally, may involve checking the wiring and connections to ensure proper functionality. |
KM-ASSYH2-06 | 66 | M7065 | Front section PLC1-M7065-retraction abnormality of the front positioning cylinder in the pressing area-X75 | Organizational Abnormality | The solution for the error Front section PLC1-M7065-retraction abnormality of the front positioning cylinder in the pressing area-X75 requires identifying and correcting the root cause of the problem. |
KM-ASSYH2-06 | 68 | M7067 | Front section PLC1-M7067-pressure area side positioning cylinder retraction abnormality-X73 | Organizational Abnormality | The solution for the error "Front section PLC1-M7067-pressure area side positioning cylinder retraction abnormality-X73" would depend on the specifics of the malfunction, but may involve |
KM-ASSYH2-06 | 69 | M7068 | Front section PLC1-M7068-pressure area lower pressure cylinder 1 rises abnormally-X76 | Organizational Abnormality | There are different possible causes of the described error, and the solution may depend on the specific root cause. It is recommended to consult the technical manual or contact the equipment manufacturer for more information and instructions on how to fix the issue. The basic steps may |
KM-ASSYH2-06 | 200 | M7039 | Rear section PLC2-M7039-the working area side positioning cylinder retracts abnormally, please check the sensor X55 | Sensor abnormality | The solution for the error with Rear section PLC2-M7039 and the abnormal retraction of the working area side positioning cylinder is to check and possibly replace sensor X55. This sensor controls the positioning |
KM-ASSYH2-06 | 213 | M7052 | Rear section PLC2-M7052-the vacuum is abnormal when taking off the upper cover, please check whether the X57 vacuum is abnormal | Electronic control abnormality | The solution to the error of abnormal vacuum in the rear section PLC2-M7052 when taking off the upper cover is to check whether the X57 vacuum is abnormal. |
KM-ASSYH2-06 | 55 | M7054 | The front-end PLC1-M7054-No. 2 product failed to scan the code, please check whether the barcode is abnormal | Visual abnormality | The solution for the error is to check whether the barcode is abnormal or damaged. If the barcode is fine, it could be possible that there is a problem with the scanner or the software used for scanning. In such cases, |