MACHINE_NO
stringclasses
48 values
ERROR_ID
int64
1
999
ERROR_CODE
stringclasses
245 values
ERROR_DESC
stringlengths
14
179
ERROR_CATEGORY1
stringclasses
11 values
SOLUTION
stringlengths
40
290
KM-ASSYH2-05
29
M7028
The communication enable between the front-end PLC1-M7028-PLC1 and PLC2 is abnormal, please check the communication line
Electronic control abnormality
The solution for the communication enable error between the front-end PLC1-M7028-PLC1 and PLC2 is to check the communication line for any potential issues such as physical damage or electromagnetic interference. It
KM-ASSYH2-05
30
M7029
Front section PLC1-M7029-the cylinder is not in the safe position when returning to the origin, please reset the cylinder first
Abnormal personnel operation
The solution for the error described in the question is to reset the cylinder first before returning to the origin, which will put the cylinder back in the safe position. This step is necessary to ensure that the cylinder is properly secured before it can
KM-ASSYH2-05
31
M7030
Front section PLC1-M7030-There is material on the material throwing platform, please take it away first
Abnormal personnel operation
The error message "Front section PLC1-M7030: There is material on the material throwing platform, please take it away first?" usually indicates that a layer of material is jamming the platform of a material handling system. The
KM-ASSYH2-05
32
M7031
Front stage PLC1-M7031-after switching the model, please perform a width adjustment reset first
Abnormal personnel operation
The solution to the error "Front stage PLC1-M7031-after switching the model, please perform a width adjustment reset first" is to perform a width adjustment reset before proceeding with the new PLC model.
KM-ASSYH2-05
33
M7032
Front section PLC1-M7032-the front buffer conveyor belt feeding operation timeout, please check sensor X50
Sensor abnormality
To solve the Front section PLC1-M7032 error, you should first check the sensor X50 to ensure it is properly functioning. If the sensor is found to be faulty, then replace it or troubleshoot the
KM-ASSYH2-04
229
M7068
Rear section-M7068-the rear suction nozzle presses down the cylinder-liter, and the extension is abnormal, please check the sensor X34
Sensor abnormality
The solution to the error with Rear section-M7068-the rear suction nozzle presses down on the cylinder-liter, and the extension is abnormal may involve checking sensor X34.
KM-ASSYH2-04
43
M7042
Front section - M7042 - upper cover front positioning cylinder - extension (front), extension is abnormal, please check sensor X45
Sensor abnormality
The solution for the error described as Front section - M7042 - upper cover front positioning cylinder - extension (front), extension is abnormal, please check sensor X45, is to inspect sensor X45 for proper function
KM-ASSYH2-04
204
M7043
Rear section-M7043-upper cover front positioning cylinder-retract (front), retraction is abnormal, please check sensor X46
Sensor abnormality
The solution for the error described as Rear section-M7043-upper cover front positioning cylinder-retract (front), retraction is abnormal, please check sensor X46 involves repair or replacement of the M7
KM-ASSYH2-04
47
M7046
Front section-M7046-tilt cylinder-liter (front), abnormal extension, please check sensor X51
Sensor abnormality
The solution for abnormal extension in front section-M7046-tilt cylinder-liter due to sensor X51 malfunction may require the replacement or calibration of the sensor, as well as inspecting the cylinder shaft
KM-ASSYH2-04
208
M7047
Rear section - M7047 - tilting cylinder - lowering (front), retraction is abnormal, please check sensor X52
Sensor abnormality
The solution to the error described as Rear section - M7047 - tilting cylinder - lowering (front), retraction is abnormal, please check sensor X52 involves checking the sensor X52 to ensure it is
KM-ASSYH2-04
211
M7050
Rear section-M7050-upper cover front positioning cylinder-extension (middle), extension is abnormal, please check sensor X56
Sensor abnormality
The solution for the described error on M7050 machine with abnormal rear section extension likely involves fixing or replacing faulty sensor X56.
KM-ASSYH2-04
54
M7053
Front section-M7053-push PCB cylinder-retract (middle), retraction is abnormal, please check sensor X61
Sensor abnormality
The M7053-push PCB cylinder-retract error can be resolved by checking sensor X61. This sensor detects the position of the PCB cylinder and could be faulty if it is not functioning correctly.
KM-ASSYH2-04
215
M7054
Rear section-M7054-tilt cylinder-rising (middle), abnormal extension, please check sensor X62
Sensor abnormality
The solution for the error described as Rear section-M7054-tilt cylinder-rising (middle), abnormal extension, please check sensor X62 is to reset the sensor X62 and check its connection.
KM-ASSYH2-04
58
M7057
Front section-M7057-upper cover side positioning cylinder (rear), retraction abnormality, please check sensor X66
Sensor abnormality
The solution for the described error of the M7057 positioning cylinder abnormality with sensor X66 may require checking the sensor for proper functioning, calibration, or replacement. Additionally, reviewing the control logic and hardware components
KM-ASSYH2-04
50
M7049
Front section-M7049-upper cover side positioning cylinder (middle), retraction abnormality, please check sensor X55
Sensor abnormality
The solution for the error described as Front section-M7049-upper cover side positioning cylinder (middle), retraction abnormality, please check sensor X55 is to inspect and potentially replace sensor X55. This
KM-ASSYH2-04
61
M7060
Front section - M7060 - push PCB cylinder - extension (rear), extension is abnormal, please check sensor X71
Sensor abnormality
The solution for the error "Front section - M7060 - push PCB cylinder - extension (rear), extension is abnormal, please check sensor X71" involves inspecting and possibly replacing the sensor X71 to
KM-ASSYH2-05
34
M7033
Front section PLC1-M7033-the discharging operation of the front buffer conveyor belt has timed out, please check sensor X50
Sensor abnormality
The solution to this error is to check the sensor X50 to ensure it is functioning correctly. If the sensor is causing the failure of the discharging operation, then it may need to be adjusted or replaced.
KM-ASSYH2-05
35
M7034
Front section PLC1-M7034-The feeding operation of the conveyor belt in the work area has timed out, please check sensor X51
Sensor abnormality
The solution for the described error is to reset the conveyor belt and check the sensor X51. If the sensor is not functioning properly, it should be replaced or repaired to allow the conveyor belt to resume its feeding operation.
KM-ASSYH2-05
36
M7035
Front section PLC1-M7035-work area conveyor belt discharging operation timeout, please check sensor X51
Sensor abnormality
The solution for the Front section PLC1-M7035-work area conveyor belt discharging operation timeout error may involve checking sensor X51 to ensure it is functioning properly or may require additional troubleshooting steps to
KM-ASSYH2-05
37
M7036
Front section PLC1-M7036-the working area blocking cylinder is rising abnormally, please check sensor X52
Sensor abnormality
The solution for the described error on Front section PLC1-M7036 may involve checking sensor X52, which likely detects the position of the working area blocking cylinder. The sensor could be faulty or misconfigured
KM-ASSYH2-05
38
M7037
Front section PLC1-M7037-the work area blocking cylinder is descending abnormally, please check sensor X53
Sensor abnormality
The solution for the error described could potentially involve checking sensor X53 to ensure that it is functioning properly, or it could require checking wiring connections and making any necessary repairs to the descending abnormally blocking cylinder in the front section of
KM-ASSYH2-05
39
M7038
Front section PLC1-M7038-the working area side positioning cylinder protrudes abnormally, please check sensor X54
Sensor abnormality
The error message indicates that the working area side positioning cylinder protrudes abnormally. The possible solution could involve checking the sensor X54 to ensure that it is functioning correctly. If the sensor is malfunctioning, it may need
KM-ASSYH2-05
49
M7048
Front section PLC1-M7048-the picking clamp is rising abnormally, please check the sensor-X60
Sensor abnormality
The solution for the error described as Front section PLC1-M7048-the picking clamp is rising abnormally, please check the sensor-X60 is to inspect and maintain the sensor X60 to ensure it
KM-ASSYH2-05
50
M7049
Front section PLC1-M7049-the picking clamp has dropped abnormally, please check the sensor-X61
Sensor abnormality
The error message "Front section PLC1-M7049-the picking clamp has dropped abnormally, please check the sensor-X61" refers to a specific type of error that may occur in a machine control system
KM-ASSYH2-05
51
M7050
Front section PLC1-M7050-the discharge clamp claw rises abnormally, please check the sensor-X62
Sensor abnormality
The solution for the error "Front section PLC1-M7050-the discharge clamp claw rises abnormally, please check the sensor-X62" could involve checking the X62 sensor's
KM-ASSYH2-05
52
M7051
Front section PLC1-M7051-the discharging clamp jaw has dropped abnormally, please check the sensor-X63
Sensor abnormality
The solution for the error described as Front section PLC1-M7051-the discharging clamp jaw has dropped abnormally, please check the sensor-X63 is to inspect the sensor-X63 for
KM-ASSYH2-05
54
M7053
The previous section PLC1-M7053-Product No. 1 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The error message indicates that the barcode scanned by PLC code is abnormal and therefore did not match to the expected Product No. To resolve the issue, the barcode should be checked for errors or if it belongs to a different product,
KM-ASSYH2-05
55
M7054
The front-end PLC1-M7054-No. 2 product failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution for the error is to check whether the barcode is abnormal or damaged. If the barcode is fine, it could be possible that there is a problem with the scanner or the software used for scanning. In such cases,
KM-ASSYH2-05
56
M7055
The front section PLC1-M7055-Product No. 3 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The problem described is likely caused by a malfunctioning barcode reader or barcode that is abnormal. Possible solutions include a replacement or calibration of the barcode reader, testing of the barcode using a different reader or device, or
KM-ASSYH2-05
58
M7057
The previous section PLC1-M7057-Product No. 5 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution for the error "The previous section PLC1-M7057-Product No. 5 failed to scan the code, please check whether the barcode is abnormal?" can be checked by verifying if the barcode
KM-ASSYH2-05
59
M7058
The front section PLC1-M7058-Product No. 6 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution for the error could involve first checking the barcode for any abnormalities, then ensuring that the barcode laser scanner is functioning properly, and updating any necessary software or firmware on the PLC. If the problem persists,
KM-ASSYH2-05
60
M7059
Front section PLC1-M7059-camera photo recognition failed
Visual abnormality
The error "Front section PLC1-M7059-camera photo recognition failed" indicates that the photo recognition function of the M7059 camera installed on PLC1 in the front section has failed. To resolve this issue
KM-ASSYH2-05
61
M7060
Front stage PLC1-M7060-Pressure value reading failed, please check
Electronic control abnormality
The solution to Front stage PLC1-M7060-Pressure value reading failed error is to check if the connection between the pressure sensor and the PLC is secure and functioning correctly. Also, ensure that the PLC is powered
KM-ASSYH2-05
65
M7064
Front section PLC1-M7064-the front positioning cylinder of the pressing area protrudes abnormally-X74
Organizational Abnormality
The solution to the X74 error in PLC1-M7064, where the front positioning cylinder of the pressing area protrudes abnormally, may involve checking the wiring and connections to ensure proper functionality.
KM-ASSYH2-05
66
M7065
Front section PLC1-M7065-retraction abnormality of the front positioning cylinder in the pressing area-X75
Organizational Abnormality
The solution for the error Front section PLC1-M7065-retraction abnormality of the front positioning cylinder in the pressing area-X75 requires identifying and correcting the root cause of the problem.
KM-ASSYH2-05
67
M7066
Front section PLC1-M7066-pressure area side positioning cylinder protrusion abnormality-X72
Organizational Abnormality
The solution for Front section PLC1-M7066-pressure area side positioning cylinder protrusion abnormality-X72 error involves identifying the root cause of the issue, performing maintenance or repairs on the affected
KM-ASSYH2-05
68
M7067
Front section PLC1-M7067-pressure area side positioning cylinder retraction abnormality-X73
Organizational Abnormality
The solution for the error "Front section PLC1-M7067-pressure area side positioning cylinder retraction abnormality-X73" would depend on the specifics of the malfunction, but may involve
KM-ASSYH2-05
69
M7068
Front section PLC1-M7068-pressure area lower pressure cylinder 1 rises abnormally-X76
Organizational Abnormality
There are different possible causes of the described error, and the solution may depend on the specific root cause. It is recommended to consult the technical manual or contact the equipment manufacturer for more information and instructions on how to fix the issue. The basic steps may
KM-ASSYH2-05
131
M7130
Front section PLC1-M7130-Please remove the TRAY plate from the conveyor belt first
Abnormal personnel operation
The solution to the error "Front section PLC1-M7130-Please remove the TRAY plate from the conveyor belt first" is to physically remove the tray plate from the conveyor belt before attempting to process any items.
KM-ASSYH2-05
161
M7000
The back-end PLC2-M7000-starts to detect that there is material in the work area, please confirm the status of the work area
Abnormal personnel operation
The solution for the error would be to visually inspect the work area to confirm if there is any material present. Once the area is clear, the PLC can be restarted, and the error should no longer occur.
KM-ASSYH2-05
177
M7016
When the rear section PLC2-M7016-EMO&&DOOR is opened, please check the safety door or emergency stop X17
Abnormal personnel operation
The solution for the error you described is to ensure that the safety door or emergency stop X17 is functioning properly and has not been triggered when the PLC2-M7016-EMO&&DOOR section is opened. This
KM-ASSYH2-05
178
M7017
Backend PLC2-M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
The solution for the error "Backend PLC2-M7017-Equipment model setting is abnormal, please set the model" is to locate and reset the faulty equipment's Model Number on the Backend PLC
KM-ASSYH2-05
179
M7018
Backend PLC2-M7018-Please press the reset button before starting the automatic process
Abnormal personnel operation
The solution for the error "Backend PLC2-M7018-Please press the reset button before starting the automatic process" is to press the reset button for the PLC2-M7018 device to restart the automatic
KM-ASSYH2-05
180
M7019
Post-stage PLC2-M7019-the equipment has not returned to the origin, please perform the equipment return to the origin first
Abnormal personnel operation
The solution to the error "Post-stage PLC2-M7019-the equipment has not returned to the origin, please perform the equipment return to the origin first" involves performing an equipment return to the origin first. This ensures
KM-ASSYH2-05
181
M7020
Rear section PLC2-M7020-There is material in the pressing area, please take it away first
Abnormal personnel operation
To solve this error, you can physically remove any material present in the pressing area of PLC2-M7020. After that, restart your machine to allow it to continue functioning normally. If you still encounter the same issue after physical
KM-ASSYH2-05
182
M7021
Post-stage PLC1-M7021-the Z-axis is not in the safe position during reset, please perform return to origin first
Abnormal personnel operation
The solution for the error PLC1-M7021 "Z-axis is not in the safe position during reset, please perform return to origin first" is to ensure that the Z-axis is in its safe position before resetting
KM-ASSYH2-05
183
M7022
Post-stage PLC1-M7022-timed out 10S while waiting for the scan code result
Visual abnormality
The solution to the error Post-stage PLC1-M7022-timed out 10S while waiting for the scan code result, is to increase the time out duration for the scan code in the device configuration settings.
KM-ASSYH2-05
184
M7023
Backend PLC1-M7023-timed out 10S waiting for the camera to take pictures
Visual abnormality
The solution for the error described as Backend PLC1-M7023-timed out 10S waiting for the camera to take pictures involves resetting or reinitializing the camera, checking for any software or firmware
KM-ASSYH2-05
185
M7024
Backend PLC1-M7024-waiting for the next camera to take pictures timed out 10S
Visual abnormality
The solution for the error "Backend PLC1-M7024-waiting for the next camera to take pictures timed out 10S" could possibly involve checking if there are any conflicts with camera software or hardware, ver
KM-ASSYH2-05
186
M7025
Backend PLC1-M7025-timeout 10S waiting for the host computer to reply to the assembly point
Machine communication abnormality
The solution for the error "Backend PLC1-M7025-timeout 10S waiting for the host computer to reply to the assembly point" is to ensure that the host computer is properly configured and accessible by the PLC
KM-ASSYH2-05
187
M7026
Post-stage PLC1-M7026-timed out 10S while waiting for the host computer to reply to the pressing result
Machine communication abnormality
This error typically indicates that the PLC waits for more than 10 seconds for the host computer to reply to the pressing result. It may be caused by network issues or slow communication between the devices. One solution is to check the network connection
KM-ASSYH2-05
188
M7027
Post-stage PLC1-M7027-waiting for the host computer to reply LINK result timed out 10S
Machine communication abnormality
The error "Post-stage PLC1-M7027-waiting for the host computer to reply LINK result timed out 10S" indicates that the PLC is waiting for a response from the host computer,
KM-ASSYH2-05
189
M7028
The communication enable between the back-end PLC2-M7028-PLC1 and PLC2 is abnormal, please check the communication line
Electronic control abnormality
It's recommended to check the communication line between the back-end PLC2-M7028-PLC1 and PLC2 to ensure that there are no issues, such as cable damage or loose connections, that may be
KM-ASSYH2-05
190
M7029
Rear section PLC2-M7029-the cylinder is not in the safe position when returning to the origin, please reset the cylinder first
Abnormal personnel operation
To resolve the error "Rear section PLC2-M7029-cylinder is not in the safe position when returning to the origin, please reset the cylinder first," you need to manually reset the cylinder to the
KM-ASSYH2-05
191
M7030
Rear section PLC2-M7030-There is material on the material throwing platform, please take it away first
Abnormal personnel operation
The solution for the error "Rear section PLC2-M7030-There is material on the material throwing platform, please take it away first?" involves physical removal of any materials present on the material throw platform before continuing with the
KM-ASSYH2-05
192
M7031
Backend PLC2-M7031-After switching the model, please perform a width adjustment reset first
Abnormal personnel operation
The solution to the error described as "Backend PLC2-M7031-After switching the model, please perform a width adjustment reset first" is to perform a width adjustment reset before switching the model in the PLC2
KM-ASSYH2-05
193
M7032
Back-end PLC2-M7032-the front buffer conveyor belt feeding operation timeout, please check sensor X50
Sensor abnormality
The solution for the error described as Back-end PLC2-M7032-the front buffer conveyor belt feeding operation timeout, please check sensor X50, is to check the sensor X50 to ensure it is functioning
KM-ASSYH2-05
194
M7033
Rear section PLC2-M7033-the discharging operation of the front buffer conveyor belt has timed out, please check the sensor X50
Sensor abnormality
The solution for the error "Rear section PLC2-M7033-the discharging operation of the front buffer conveyor belt has timed out, please check the sensor X50" is to check the sensor X
KM-ASSYH2-05
195
M7034
Rear-end PLC2-M7034-Work area conveyor belt feeding operation timeout, please check sensor X51
Sensor abnormality
The solution to the described error requiring attention to sensor X51 on the rear-end PLC2-M7034-Work area conveyor belt feeding operation timeout is to check the condition of the sensor and verify that it is functioning
KM-ASSYH2-05
196
M7035
Rear section PLC2-M7035-The discharging operation of the conveyor belt in the work area has timed out, please check sensor X51
Sensor abnormality
The solution to the error described as "Rear Section PLC2-M7035-The discharging operation of the conveyor belt in the work area has timed out, please check sensor X51" is to reset
KM-ASSYH2-05
40
M7039
Front section PLC1-M7039-the working area side positioning cylinder retracts abnormally, please check sensor X55
Sensor abnormality
The solution for the error described as Front section PLC1-M7039-the working area side positioning cylinder retracts abnormally, please check sensor X55, would be to first check the sensor X5
KM-ASSYH2-05
53
M7052
The front section PLC1-M7052-vacuum is abnormal when removing the upper cover, please check whether the X57 vacuum is abnormal
Electronic control abnormality
Check the X57 vacuum relay by opening its control circuit and monitoring it for any faults, including blown fuses, missing parts, or visible damage. You should also check the vacuum level in the X57 vacuum relay by using a vacuum
KM-ASSYH2-05
57
M7056
The front-end PLC1-M7056-No. 4 product failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution for this error is to check the barcode. If it is abnormal, fix it before scanning again. If the barcode is correct, check the PLC settings and ensure the barcode scanner is properly calibrated and
KM-ASSYH2-05
27
M7026
Front-stage PLC1-M7026-timed out 10S while waiting for the host computer to reply to the pressing result
Machine communication abnormality
The Front-stage PLC1-M7026-timed out 10S error is usually caused by a communication issue between the PLC and the host computer. Possible solutions include checking the communication settings, restarting the
KM-ASSYH2-06
131
M7130
Front section PLC1-M7130-Please remove the TRAY plate from the conveyor belt first
Abnormal personnel operation
The solution to the error "Front section PLC1-M7130-Please remove the TRAY plate from the conveyor belt first" is to physically remove the tray plate from the conveyor belt before attempting to process any items.
KM-ASSYH2-06
161
M7000
The back-end PLC2-M7000-starts to detect that there is material in the work area, please confirm the status of the work area
Abnormal personnel operation
The solution for the error would be to visually inspect the work area to confirm if there is any material present. Once the area is clear, the PLC can be restarted, and the error should no longer occur.
KM-ASSYH2-06
177
M7016
When the rear section PLC2-M7016-EMO&&DOOR is opened, please check the safety door or emergency stop X17
Abnormal personnel operation
The solution for the error you described is to ensure that the safety door or emergency stop X17 is functioning properly and has not been triggered when the PLC2-M7016-EMO&&DOOR section is opened. This
KM-ASSYH2-06
178
M7017
Backend PLC2-M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
The solution for the error "Backend PLC2-M7017-Equipment model setting is abnormal, please set the model" is to locate and reset the faulty equipment's Model Number on the Backend PLC
KM-ASSYH2-06
179
M7018
Backend PLC2-M7018-Please press the reset button before starting the automatic process
Abnormal personnel operation
The solution for the error "Backend PLC2-M7018-Please press the reset button before starting the automatic process" is to press the reset button for the PLC2-M7018 device to restart the automatic
KM-ASSYH2-06
180
M7019
Post-stage PLC2-M7019-the equipment has not returned to the origin, please perform the equipment return to the origin first
Abnormal personnel operation
The solution to the error "Post-stage PLC2-M7019-the equipment has not returned to the origin, please perform the equipment return to the origin first" involves performing an equipment return to the origin first. This ensures
KM-ASSYH2-06
181
M7020
Rear section PLC2-M7020-There is material in the pressing area, please take it away first
Abnormal personnel operation
To solve this error, you can physically remove any material present in the pressing area of PLC2-M7020. After that, restart your machine to allow it to continue functioning normally. If you still encounter the same issue after physical
KM-ASSYH2-06
182
M7021
Post-stage PLC1-M7021-the Z-axis is not in the safe position during reset, please perform return to origin first
Abnormal personnel operation
The solution for the error PLC1-M7021 "Z-axis is not in the safe position during reset, please perform return to origin first" is to ensure that the Z-axis is in its safe position before resetting
KM-ASSYH2-06
183
M7022
Post-stage PLC1-M7022-timed out 10S while waiting for the scan code result
Visual abnormality
The solution to the error Post-stage PLC1-M7022-timed out 10S while waiting for the scan code result, is to increase the time out duration for the scan code in the device configuration settings.
KM-ASSYH2-06
184
M7023
Backend PLC1-M7023-timed out 10S waiting for the camera to take pictures
Visual abnormality
The solution for the error described as Backend PLC1-M7023-timed out 10S waiting for the camera to take pictures involves resetting or reinitializing the camera, checking for any software or firmware
KM-ASSYH2-06
185
M7024
Backend PLC1-M7024-waiting for the next camera to take pictures timed out 10S
Visual abnormality
The solution for the error "Backend PLC1-M7024-waiting for the next camera to take pictures timed out 10S" could possibly involve checking if there are any conflicts with camera software or hardware, ver
KM-ASSYH2-06
186
M7025
Backend PLC1-M7025-timeout 10S waiting for the host computer to reply to the assembly point
Machine communication abnormality
The solution for the error "Backend PLC1-M7025-timeout 10S waiting for the host computer to reply to the assembly point" is to ensure that the host computer is properly configured and accessible by the PLC
KM-ASSYH2-06
187
M7026
Post-stage PLC1-M7026-timed out 10S while waiting for the host computer to reply to the pressing result
Machine communication abnormality
This error typically indicates that the PLC waits for more than 10 seconds for the host computer to reply to the pressing result. It may be caused by network issues or slow communication between the devices. One solution is to check the network connection
KM-ASSYH2-06
188
M7027
Post-stage PLC1-M7027-waiting for the host computer to reply LINK result timed out 10S
Machine communication abnormality
The error "Post-stage PLC1-M7027-waiting for the host computer to reply LINK result timed out 10S" indicates that the PLC is waiting for a response from the host computer,
KM-ASSYH2-06
189
M7028
The communication enable between the back-end PLC2-M7028-PLC1 and PLC2 is abnormal, please check the communication line
Electronic control abnormality
It's recommended to check the communication line between the back-end PLC2-M7028-PLC1 and PLC2 to ensure that there are no issues, such as cable damage or loose connections, that may be
KM-ASSYH2-06
38
M7037
Front section PLC1-M7037-the work area blocking cylinder is descending abnormally, please check sensor X53
Sensor abnormality
The solution for the error described could potentially involve checking sensor X53 to ensure that it is functioning properly, or it could require checking wiring connections and making any necessary repairs to the descending abnormally blocking cylinder in the front section of
KM-ASSYH2-06
39
M7038
Front section PLC1-M7038-the working area side positioning cylinder protrudes abnormally, please check sensor X54
Sensor abnormality
The error message indicates that the working area side positioning cylinder protrudes abnormally. The possible solution could involve checking the sensor X54 to ensure that it is functioning correctly. If the sensor is malfunctioning, it may need
KM-ASSYH2-06
40
M7039
Front section PLC1-M7039-the working area side positioning cylinder retracts abnormally, please check sensor X55
Sensor abnormality
The solution for the error described as Front section PLC1-M7039-the working area side positioning cylinder retracts abnormally, please check sensor X55, would be to first check the sensor X5
KM-ASSYH2-06
49
M7048
Front section PLC1-M7048-the picking clamp is rising abnormally, please check the sensor-X60
Sensor abnormality
The solution for the error described as Front section PLC1-M7048-the picking clamp is rising abnormally, please check the sensor-X60 is to inspect and maintain the sensor X60 to ensure it
KM-ASSYH2-06
50
M7049
Front section PLC1-M7049-the picking clamp has dropped abnormally, please check the sensor-X61
Sensor abnormality
The error message "Front section PLC1-M7049-the picking clamp has dropped abnormally, please check the sensor-X61" refers to a specific type of error that may occur in a machine control system
KM-ASSYH2-06
51
M7050
Front section PLC1-M7050-the discharge clamp claw rises abnormally, please check the sensor-X62
Sensor abnormality
The solution for the error "Front section PLC1-M7050-the discharge clamp claw rises abnormally, please check the sensor-X62" could involve checking the X62 sensor's
KM-ASSYH2-06
52
M7051
Front section PLC1-M7051-the discharging clamp jaw has dropped abnormally, please check the sensor-X63
Sensor abnormality
The solution for the error described as Front section PLC1-M7051-the discharging clamp jaw has dropped abnormally, please check the sensor-X63 is to inspect the sensor-X63 for
KM-ASSYH2-06
53
M7052
The front section PLC1-M7052-vacuum is abnormal when removing the upper cover, please check whether the X57 vacuum is abnormal
Electronic control abnormality
Check the X57 vacuum relay by opening its control circuit and monitoring it for any faults, including blown fuses, missing parts, or visible damage. You should also check the vacuum level in the X57 vacuum relay by using a vacuum
KM-ASSYH2-06
54
M7053
The previous section PLC1-M7053-Product No. 1 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The error message indicates that the barcode scanned by PLC code is abnormal and therefore did not match to the expected Product No. To resolve the issue, the barcode should be checked for errors or if it belongs to a different product,
KM-ASSYH2-06
56
M7055
The front section PLC1-M7055-Product No. 3 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The problem described is likely caused by a malfunctioning barcode reader or barcode that is abnormal. Possible solutions include a replacement or calibration of the barcode reader, testing of the barcode using a different reader or device, or
KM-ASSYH2-06
57
M7056
The front-end PLC1-M7056-No. 4 product failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution for this error is to check the barcode. If it is abnormal, fix it before scanning again. If the barcode is correct, check the PLC settings and ensure the barcode scanner is properly calibrated and
KM-ASSYH2-06
58
M7057
The previous section PLC1-M7057-Product No. 5 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution for the error "The previous section PLC1-M7057-Product No. 5 failed to scan the code, please check whether the barcode is abnormal?" can be checked by verifying if the barcode
KM-ASSYH2-06
59
M7058
The front section PLC1-M7058-Product No. 6 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution for the error could involve first checking the barcode for any abnormalities, then ensuring that the barcode laser scanner is functioning properly, and updating any necessary software or firmware on the PLC. If the problem persists,
KM-ASSYH2-06
61
M7060
Front stage PLC1-M7060-Pressure value reading failed, please check
Electronic control abnormality
The solution to Front stage PLC1-M7060-Pressure value reading failed error is to check if the connection between the pressure sensor and the PLC is secure and functioning correctly. Also, ensure that the PLC is powered
KM-ASSYH2-06
65
M7064
Front section PLC1-M7064-the front positioning cylinder of the pressing area protrudes abnormally-X74
Organizational Abnormality
The solution to the X74 error in PLC1-M7064, where the front positioning cylinder of the pressing area protrudes abnormally, may involve checking the wiring and connections to ensure proper functionality.
KM-ASSYH2-06
66
M7065
Front section PLC1-M7065-retraction abnormality of the front positioning cylinder in the pressing area-X75
Organizational Abnormality
The solution for the error Front section PLC1-M7065-retraction abnormality of the front positioning cylinder in the pressing area-X75 requires identifying and correcting the root cause of the problem.
KM-ASSYH2-06
68
M7067
Front section PLC1-M7067-pressure area side positioning cylinder retraction abnormality-X73
Organizational Abnormality
The solution for the error "Front section PLC1-M7067-pressure area side positioning cylinder retraction abnormality-X73" would depend on the specifics of the malfunction, but may involve
KM-ASSYH2-06
69
M7068
Front section PLC1-M7068-pressure area lower pressure cylinder 1 rises abnormally-X76
Organizational Abnormality
There are different possible causes of the described error, and the solution may depend on the specific root cause. It is recommended to consult the technical manual or contact the equipment manufacturer for more information and instructions on how to fix the issue. The basic steps may
KM-ASSYH2-06
200
M7039
Rear section PLC2-M7039-the working area side positioning cylinder retracts abnormally, please check the sensor X55
Sensor abnormality
The solution for the error with Rear section PLC2-M7039 and the abnormal retraction of the working area side positioning cylinder is to check and possibly replace sensor X55. This sensor controls the positioning
KM-ASSYH2-06
213
M7052
Rear section PLC2-M7052-the vacuum is abnormal when taking off the upper cover, please check whether the X57 vacuum is abnormal
Electronic control abnormality
The solution to the error of abnormal vacuum in the rear section PLC2-M7052 when taking off the upper cover is to check whether the X57 vacuum is abnormal.
KM-ASSYH2-06
55
M7054
The front-end PLC1-M7054-No. 2 product failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution for the error is to check whether the barcode is abnormal or damaged. If the barcode is fine, it could be possible that there is a problem with the scanner or the software used for scanning. In such cases,