MACHINE_NO
stringclasses
48 values
ERROR_ID
int64
1
999
ERROR_CODE
stringclasses
245 values
ERROR_DESC
stringlengths
14
179
ERROR_CATEGORY1
stringclasses
11 values
SOLUTION
stringlengths
40
290
KM-ASSYH2-06
218
M7057
The backend PLC2-M7057-Product No. 5 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution to the error "The backend PLC2-M7057-Product No. 5 failed to scan the code, please check whether the barcode is abnormal?" is to verify that the barcode is correctly printed and
KM-ASSYH2-06
190
M7029
Rear section PLC2-M7029-the cylinder is not in the safe position when returning to the origin, please reset the cylinder first
Abnormal personnel operation
To resolve the error "Rear section PLC2-M7029-cylinder is not in the safe position when returning to the origin, please reset the cylinder first," you need to manually reset the cylinder to the
KM-ASSYH2-06
191
M7030
Rear section PLC2-M7030-There is material on the material throwing platform, please take it away first
Abnormal personnel operation
The solution for the error "Rear section PLC2-M7030-There is material on the material throwing platform, please take it away first?" involves physical removal of any materials present on the material throw platform before continuing with the
KM-ASSYH2-06
192
M7031
Backend PLC2-M7031-After switching the model, please perform a width adjustment reset first
Abnormal personnel operation
The solution to the error described as "Backend PLC2-M7031-After switching the model, please perform a width adjustment reset first" is to perform a width adjustment reset before switching the model in the PLC2
KM-ASSYH2-06
193
M7032
Back-end PLC2-M7032-the front buffer conveyor belt feeding operation timeout, please check sensor X50
Sensor abnormality
The solution for the error described as Back-end PLC2-M7032-the front buffer conveyor belt feeding operation timeout, please check sensor X50, is to check the sensor X50 to ensure it is functioning
KM-ASSYH2-06
194
M7033
Rear section PLC2-M7033-the discharging operation of the front buffer conveyor belt has timed out, please check the sensor X50
Sensor abnormality
The solution for the error "Rear section PLC2-M7033-the discharging operation of the front buffer conveyor belt has timed out, please check the sensor X50" is to check the sensor X
KM-ASSYH2-06
195
M7034
Rear-end PLC2-M7034-Work area conveyor belt feeding operation timeout, please check sensor X51
Sensor abnormality
The solution to the described error requiring attention to sensor X51 on the rear-end PLC2-M7034-Work area conveyor belt feeding operation timeout is to check the condition of the sensor and verify that it is functioning
KM-ASSYH2-06
196
M7035
Rear section PLC2-M7035-The discharging operation of the conveyor belt in the work area has timed out, please check sensor X51
Sensor abnormality
The solution to the error described as "Rear Section PLC2-M7035-The discharging operation of the conveyor belt in the work area has timed out, please check sensor X51" is to reset
KM-ASSYH2-06
197
M7036
Rear section PLC2-M7036-the working area blocking cylinder is rising abnormally, please check sensor X52
Sensor abnormality
The solution for this error may involve checking the sensor X52 for any blockages or malfunctions that may be preventing the working area blocking cylinder from functioning properly. In some cases, it may also be necessary to adjust the cylinder settings to
KM-ASSYH2-06
198
M7037
Rear section PLC2-M7037-the working area blocking cylinder is abnormally descending, please check sensor X53
Sensor abnormality
To solve the error with the Rear section PLC2-M7037 and the abnormally descending working area blocking cylinder, the sensor X53 should be checked for any malfunctions or failures. The sensor provides information
KM-ASSYH2-06
199
M7038
Rear section PLC2-M7038-the working area side positioning cylinder extends abnormally, please check sensor X54
Sensor abnormality
The solution for the error described as "Rear section PLC2-M7038-the working area side positioning cylinder extends abnormally, please check sensor X54" may involve assessing the status of sensor X
KM-ASSYH2-06
210
M7049
Rear section PLC2-M7049-the picking clamp has dropped abnormally, please check the sensor-X61
Sensor abnormality
The solution to the error described as Rear section PLC2-M7049-the picking clamp has dropped abnormally, please check the sensor-X61 would be to investigate the sensor and ensure it is working correctly
KM-ASSYH2-06
211
M7050
Rear section PLC2-M7050-the discharge clamp claw rises abnormally, please check the sensor-X62
Sensor abnormality
The solution for the error described for Rear section PLC2-M7050 is to verify the connection of sensor-X62 and check its output for any unusual readings. The discharge clamp claw may be rising
KM-ASSYH2-06
212
M7051
Rear section PLC2-M7051-the discharge clamp is abnormally falling, please check the sensor-X63
Sensor abnormality
The solution for the error described as Rear section PLC2-M7051 is to check the discharge clamp sensor-X63 for an abnormality. If the sensor is found to be faulty, the cl
KM-ASSYH2-06
214
M7053
The backend PLC2-M7053-Product No. 1 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution to the PLC2-M7053-Product No. 1 failed to scan code error is to check if the barcode is readable or abnormal. In this case, it is important to verify that the bar
KM-ASSYH2-06
215
M7054
The backend PLC2-M7054-Product No. 2 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The error message "PLC2-M7054 Product No. 2 failed to scan the code" usually means either the PLC or barcode scanner hardware is faulty, or the barcode is abnormal or incompatible
KM-ASSYH2-06
216
M7055
The backend PLC2-M7055-Product No. 3 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution for the error described as "The backend PLC2-M7055-Product No. 3 failed to scan the code, please check whether the barcode is abnormal?" is to either verify that the barcode is
KM-ASSYH2-06
217
M7056
The backend PLC2-M7056-Product No. 4 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
There could be several possible reasons why the PLC2-M7056-Product No. 4 failed to scan the code. It is recommended to check if the barcode is damaged, dirty, or if there is any misalign
KM-ASSYH2-06
219
M7058
The backend PLC2-M7058-Product No. 6 failed to scan the code, please check whether the barcode is abnormal
Visual abnormality
The solution for the error "The backend PLC2-M7058-Product No. 6 failed to scan the code, please check whether the barcode is abnormal" is to review the barcode for any errors or anom
KM-ASSYH2-06
220
M7059
Backend PLC2-M7059-camera photo recognition failed
Visual abnormality
The solution for the PLC2-M7059-camera photo recognition error could be to check if the camera is connected and has clear coverage of the area to be recognized. If the issue persists, software updates or hardware replacement may
KM-ASSYH2-06
221
M7060
Post-stage PLC2-M7060-Pressure value reading failed, please check
Electronic control abnormality
The solution for the error "Post-stage PLC2-M7060-Pressure value reading failed, please check?" may vary depending on the specific issue. However, some potential steps to troubleshoot the issue include resetting
KM-ASSYH2-06
225
M7064
Rear section PLC2-M7064-Extrusion abnormality of the front positioning cylinder in the pressing area-X74
Organizational Abnormality
The solution for the Rear section PLC2-M7064-Extrusion abnormality of the front positioning cylinder in the pressing area-X74 would involve identifying the root cause of the issue, making necessary
KM-ASSYH2-06
227
M7066
Rear section PLC2-M7066-Extrusion abnormality of side positioning cylinder in pressing area-X72
Organizational Abnormality
The solution for the error described as Rear section PLC2-M7066-Extrusion abnormality of side positioning cylinder in pressing area-X72 is likely related to a malfunction in the positioning
KM-ASSYH2-06
228
M7067
Rear section PLC2-M7067-pressure area side positioning cylinder retraction abnormality-X73
Organizational Abnormality
The error Rear section PLC2-M7067-pressure area side positioning cylinder retraction abnormality-X73 may be due to issues with the PLC or the connecting hardware between the PLC and
KM-ASSYH2-06
229
M7068
Rear section PLC2-M7068-pressure area lower pressure cylinder 1 rises abnormally-X76
Organizational Abnormality
The solution to the Rear section PLC2-M7068-pressure area lower pressure cylinder 1 rises abnormally-X76 error typically involves adjusting the pressure settings on the affected cylinder to ensure
KM-ASSYH2-06
291
M7130
Rear section PLC2-M7130-Please remove the TRAY plate from the conveyor belt first
Abnormal personnel operation
One possible solution for this error is to physically remove the TRAY plate from the conveyor belt before the PLC2-M7130 can be accessed. This should prevent any interference or damage to the belt caused by the plate's
KM-ASSYH2-06
1
M7000
The front-end PLC1-M7000-starts to detect that there is material in the work area, please confirm the status of the work area
Abnormal personnel operation
Unfortunately, without any context or additional information provided, it's impossible to provide a specific solution to the described error. However, it is recommended to check the documentation and user manuals for the PLC1-M7000, as
KM-ASSYH2-06
17
M7016
If the front section PLC1-M7016-EMO&&DOOR is opened, please check the safety door or emergency stop X17
Abnormal personnel operation
The solution for this error is to check the safety door or emergency stop X17 when the front section PLC1-M7016-EMO&&DOOR is opened.
KM-ASSYH2-06
18
M7017
Front stage PLC1-M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
The solution for the abnormal Front stage PLC1-M7017 equipment model setting is to set a new, valid model in the PLC. This can usually be done through the PLC's programming software or by physically reset
KM-ASSYH2-06
19
M7018
Front stage PLC1-M7018-Please press the reset button before starting the automatic process
Abnormal personnel operation
The solution for the Front stage PLC1-M7018 error described as "Please press the reset button before starting the automatic process" is as follows: Press the reset button before starting the automatic process. This process should restart and run
KM-ASSYH2-06
20
M7019
Previous PLC1-M7019-The equipment has not returned to the origin, please perform the equipment return to the origin first
Abnormal personnel operation
The solution to the error "Previous PLC1-M7019-The equipment has not returned to the origin, please perform the equipment return to the origin first" is to first perform the equipment return to the origin before proceeding with
KM-ASSYH2-06
21
M7020
Front section PLC1-M7020-There is material in the pressing area, please take it away first
Abnormal personnel operation
The solution for the "Pressing Area Full Error" in PLC1-M7020 is to remove any accumulated material from the pressing area before attempting to continue operation. This can be accomplished by physically removing the material or activating
KM-ASSYH2-06
22
M7021
Front stage PLC1-M7021-the Z-axis is not in the safe position during reset, please perform return to origin first
Abnormal personnel operation
The solution to the error "Front stage PLC1-M7021-the Z-axis is not in the safe position during reset" is to perform a return to origin first, which will ensure that the axis is in its safe
KM-ASSYH2-06
23
M7022
Previous section PLC1-M7022-timed out 10S while waiting for the scan code result
Visual abnormality
The solution for the error is to check the PLC's settings and ensure that the scan code result communication timeout is set correctly. If it is not working, you may need to update the PLC's firmware or contact technical support for
KM-ASSYH2-06
24
M7023
Front section PLC1-M7023-waiting for the camera to take pictures timed out 10S
Visual abnormality
The error "Front section PLC1-M7023-waiting for the camera to take pictures timed out 10S" can be resolved by checking the camera settings and ensuring that it is properly connected to the PLC
KM-ASSYH2-06
25
M7024
Front section PLC1-M7024-waiting for the next camera to take pictures timed out 10S
Visual abnormality
The solution for the error described as the front section PLC1-M7024 waiting for the next camera to take pictures timed out 10S could involve checking the camera configuration, ensuring proper camera communication, adjusting camera settings
KM-ASSYH2-06
26
M7025
Front-end PLC1-M7025-timeout 10S waiting for the host computer to reply to the assembly point
Machine communication abnormality
The solution for Front-end PLC1-M7025-timeout 10S waiting for the host computer to reply to the assembly point is to ensure that the host computer's firmware version is compatible with PLC1
KM-ASSYH2-06
27
M7026
Front-stage PLC1-M7026-timed out 10S while waiting for the host computer to reply to the pressing result
Machine communication abnormality
The Front-stage PLC1-M7026-timed out 10S error is usually caused by a communication issue between the PLC and the host computer. Possible solutions include checking the communication settings, restarting the
KM-ASSYH2-06
28
M7027
Front stage PLC1-M7027-waiting for the host computer to reply LINK result timed out 10S
Machine communication abnormality
The solution for the described error is to increase the timeout value in the Link Communication Manager settings, such as by increasing the "Reply Timeout" setting to a value of 10 seconds or higher. It's also recommended to check the
KM-ASSYH2-06
29
M7028
The communication enable between the front-end PLC1-M7028-PLC1 and PLC2 is abnormal, please check the communication line
Electronic control abnormality
The solution for the communication enable error between the front-end PLC1-M7028-PLC1 and PLC2 is to check the communication line for any potential issues such as physical damage or electromagnetic interference. It
KM-ASSYH2-06
30
M7029
Front section PLC1-M7029-the cylinder is not in the safe position when returning to the origin, please reset the cylinder first
Abnormal personnel operation
The solution for the error described in the question is to reset the cylinder first before returning to the origin, which will put the cylinder back in the safe position. This step is necessary to ensure that the cylinder is properly secured before it can
KM-ASSYH2-06
31
M7030
Front section PLC1-M7030-There is material on the material throwing platform, please take it away first
Abnormal personnel operation
The error message "Front section PLC1-M7030: There is material on the material throwing platform, please take it away first?" usually indicates that a layer of material is jamming the platform of a material handling system. The
KM-ASSYH2-06
32
M7031
Front stage PLC1-M7031-after switching the model, please perform a width adjustment reset first
Abnormal personnel operation
The solution to the error "Front stage PLC1-M7031-after switching the model, please perform a width adjustment reset first" is to perform a width adjustment reset before proceeding with the new PLC model.
KM-ASSYH2-06
33
M7032
Front section PLC1-M7032-the front buffer conveyor belt feeding operation timeout, please check sensor X50
Sensor abnormality
To solve the Front section PLC1-M7032 error, you should first check the sensor X50 to ensure it is properly functioning. If the sensor is found to be faulty, then replace it or troubleshoot the
KM-ASSYH2-06
34
M7033
Front section PLC1-M7033-the discharging operation of the front buffer conveyor belt has timed out, please check sensor X50
Sensor abnormality
The solution to this error is to check the sensor X50 to ensure it is functioning correctly. If the sensor is causing the failure of the discharging operation, then it may need to be adjusted or replaced.
KM-ASSYH2-06
35
M7034
Front section PLC1-M7034-The feeding operation of the conveyor belt in the work area has timed out, please check sensor X51
Sensor abnormality
The solution for the described error is to reset the conveyor belt and check the sensor X51. If the sensor is not functioning properly, it should be replaced or repaired to allow the conveyor belt to resume its feeding operation.
KM-ASSYH2-06
36
M7035
Front section PLC1-M7035-work area conveyor belt discharging operation timeout, please check sensor X51
Sensor abnormality
The solution for the Front section PLC1-M7035-work area conveyor belt discharging operation timeout error may involve checking sensor X51 to ensure it is functioning properly or may require additional troubleshooting steps to
KM-ASSYH2-06
37
M7036
Front section PLC1-M7036-the working area blocking cylinder is rising abnormally, please check sensor X52
Sensor abnormality
The solution for the described error on Front section PLC1-M7036 may involve checking sensor X52, which likely detects the position of the working area blocking cylinder. The sensor could be faulty or misconfigured
KM-ASSYH2-06
60
M7059
Front section PLC1-M7059-camera photo recognition failed
Visual abnormality
The error "Front section PLC1-M7059-camera photo recognition failed" indicates that the photo recognition function of the M7059 camera installed on PLC1 in the front section has failed. To resolve this issue
KM-ASSYH2-06
226
M7065
Rear section PLC2-M7065-retraction abnormality of the front positioning cylinder in the pressing area-X75
Organizational Abnormality
The Rear section PLC2-M7065 retraction abnormality of the front positioning cylinder in the pressing area X75 can be resolved by verifying the sensor wiring connections and ensuring that all equipment is functioning
KM-ASSYH2-06
67
M7066
Front section PLC1-M7066-pressure area side positioning cylinder protrusion abnormality-X72
Organizational Abnormality
The solution for Front section PLC1-M7066-pressure area side positioning cylinder protrusion abnormality-X72 error involves identifying the root cause of the issue, performing maintenance or repairs on the affected
KM-ASSYH2-06
209
M7048
Rear section PLC2-M7048-the picking clamp is rising abnormally, please check the sensor-X60
Sensor abnormality
The solution for the error Rear section PLC2-M7048 may involve checking the sensor X60 for any unusual readings or malfunction, which may be causing the picking clamp to rise abnormally. Identify
KM-ASSYH2-07
55
M7054
[Front Section] M7054-Right lifting cylinder abnormality
Machine cylinder abnormality
The solution for a front section M7054-Right lifting cylinder abnormality would involve fixing any equipment malfunctions and possibly replacing damaged components or parts to ensure proper function and performance of the affected equipment.
KM-ASSYH2-07
58
M7057
[Previous section] M7057-The left suction nozzle is abnormal in vacuum suction
Electronic control abnormality
The solution to the M7057 error often involves adjusting the suction vacuum settings and correcting any faulty hardware issues. Using the appropriate vacuum tool and removing any debris or blocks in the nozzle may also fix the issue.
KM-ASSYH2-07
59
M7058
[Previous section] M7058-Right suction nozzle is abnormal in vacuum suction
Electronic control abnormality
The solution for the error described as M7058-Right suction nozzle is abnormal in vacuum suction involves troubleshooting the nozzle to determine the cause of the problem, performing any necessary repairs, and testing
KM-ASSYH2-07
65
M7064
[Front section] M7064-The upper jacking cylinder in the Tray area is abnormal
Machine cylinder abnormality
The solution for the M7064 error in the Tray area may involve inspecting the upper jacking cylinder and addressing any abnormalities, such as replacing a faulty cylinder. The issue should be resolved as soon as possible
KM-ASSYH2-07
67
M7066
[Front section] M7066-The jacking cylinder at the lower level of the Tray area is abnormal
Machine cylinder abnormality
To resolve the error with the abnormal jacking cylinder at the lower level of the Tray area, it's recommended to check the cylinder's condition, ensure there is no leakage, lubrication of the worn parts and
KM-ASSYH2-07
69
M7068
[Previous section] M7068-The material cylinder entering the Tray section is abnormal
Machine cylinder abnormality
The solution to the error "M7068-The material cylinder entering the Tray section is abnormal?" is to address the issue by adjusting or preventing the material cylinder from entering the tray section in an abnormal manner.
KM-ASSYH2-07
161
M7000
[Later Section] M7000-Start to detect the presence of materials in the work area, please confirm the status of the work area
Abnormal personnel operation
The solution for the error described as [Later Section] M7000-Start is to confirm the status of the work area. This can be achieved by manually scanning the area using the device's sensor or by using software to
KM-ASSYH2-07
163
M7002
[Later Section] M7002-Receiving Tray Area Full Material Alarm
Abnormal personnel operation
The solution for the M7002-Receiving Tray Area Full Material Alarm error is to clear the alarm in the Materials Management system by going to the Receiving Tray Control screen and canceling the alarm. If
KM-ASSYH2-07
164
M7003
[Rear section] M7003-Incoming Tray area shortage alarm
Abnormal personnel operation
The solution to the error [Rear section] M7003-Incoming Tray area shortage alarm is to ensure that the incoming tray area has enough space to accommodate the trays. This can be done by checking the tray storage
KM-ASSYH2-07
165
M7004
[Later section] M7004-no material alarm in receiving Tray area
Abnormal personnel operation
The solution to this error involves manually triggering an alarm to alert the appropriate personnel to investigate the issue described in the earlier section.
KM-ASSYH2-07
166
M7005
[Later section] M7005-Timeout exception waiting for the host computer to reply to the detection result
Machine communication abnormality
The M7005-Timeout exception occurs when the detection result is not received within the specified time frame. The solution is to check the connection settings, including network connectivity and firewall settings, and ensure that the computer is responding within the
KM-ASSYH2-07
174
M7013
[Later Section] M7013-Origin return ended abnormally
Electronic control abnormality
This error message indicates that there was an issue with your Oracle Database during or after a migration or upgrade process. To resolve this error, you may need to try a new migration or upgrade, repair your database, or contact Oracle support for further assistance.
KM-ASSYH2-07
175
M7014
[Second paragraph] M7014-Automatic positioning ended abnormally
Electronic control abnormality
The solution to the error "M7014-Automatic positioning ended abnormally" may involve resetting the device or firmware, checking for any obstructions or interference, and contacting customer support for assistance.
KM-ASSYH2-07
176
M7015
[Later section] M7015-Manual positioning ended abnormally
Electronic control abnormality
The solution for the error "Later section M7015-Manual positioning ended abnormally" could involve correcting any misconfigured or faulty settings related to the manual positioning of the printer, such as paper size
KM-ASSYH2-07
177
M7016
[Later section] M7016-EMO&&DOOR is open, please check the safety door or emergency stop
Abnormal personnel operation
The solution for this error is to check the safety door or emergency stop, close the door and retest the system. If the problem persists, maintenance or repair may be required. It is recommended to follow the manufacturer's instructions or contact a
KM-ASSYH2-07
178
M7017
[Later section] M7017-Equipment model setting is abnormal, please set the model
Abnormal personnel operation
To resolve the error "Later section M7017-Equipment model setting is abnormal, please set the model," follow these steps: 1. Power off the device in question. 2. Reset the device to its
KM-ASSYH2-07
179
M7018
[Later Section] M7018-Please press the reset button first after starting the automatic process
Abnormal personnel operation
The solution for the error described as [Later Section] M7018 is to press the reset button before starting the automatic process. This will ensure that the device is fully reset and all previous settings are cleared, and the automatic process can
KM-ASSYH2-07
180
M7019
[Second paragraph] M7019-The device has not returned to the origin, please execute the device to return to the origin first
Abnormal personnel operation
The solution to the error M7019 "The device has not returned to the origin, please execute the device to return to the origin first?" is to follow the instructions provided on the device, which might include pressing a button or entering a
KM-ASSYH2-07
181
M7020
[Rear section] M7020-There is abnormal material on the conveyor belt during width adjustment
Abnormal personnel operation
The solution for this error is to ensure the conveyor belt is properly cleaned and any debris has been removed before attempting to adjust its width. This can be done through manual cleaning or using a designated cleaning tool provided by the equipment manufacturer. Additionally, it
KM-ASSYH2-07
182
M7021
[Later Section] M7021-Product abnormality when starting secondary positioning
Abnormal personnel operation
The solution to the error described in M7021-Product abnormality when starting secondary positioning is to ensure that the product is positioned correctly and not obstructed. Additionally, the operator should verify that all safety features are functioning properly
KM-ASSYH2-07
184
M7023
[Rear section] M7023-The conveyor belt point is abnormal, please confirm whether the point corresponds to the machine model
Abnormal personnel operation
The solution for the error M7023 is to confirm whether the conveyor belt point corresponds to the machine model. If it does not match, the user may need to update the model in the system or contact technical support for assistance.
KM-ASSYH2-07
186
M7025
[Later section] M7025-buffer area abnormal material alarm
Abnormal personnel operation
The solution for the M7025-buffer area abnormal material alarm is typically to clean or replace the buffer in question. This may involve performing maintenance or repair on the equipment, or simply removing any contaminated materials and replacing them with
KM-ASSYH2-07
187
M7026
[Later section] M7026-The left suction nozzle continuously fails abnormally
Electronic control abnormality
The solution for the error M7026-The left suction nozzle continuously fails abnormally is to check for any blockages or restrictions in the suction line of the unit and to clean any debris or foreign objects. Additionally
KM-ASSYH2-07
188
M7027
[Later section] M7027-Right suction nozzle continuous failure exception
Electronic control abnormality
The solution for the M7027-Right suction nozzle continuous failure exception could be to check for any blockages, wear and tear, or damage to the nozzle. Replacement of the nozzle may be necessary
KM-ASSYH2-07
189
M7028
[Later section] M7028-Safety door opens abnormally during return to origin
Abnormal personnel operation
The solution for the error described as M7028-Safety door opens abnormally during return to origin requires an inspection of the safety door drive system for any damage or malfunction. The door may need to be adjusted or replaced
KM-ASSYH2-07
190
M7029
[Later section] M7029-Servo operation condition abnormality
Electronic control abnormality
The solution for the error "Later section" M7029-Servo operation condition abnormality would depend on the underlying cause of the issue. Possible solutions include checking the servo hardware, calibrating the servo,
KM-ASSYH2-07
191
M7030
[Later section] Communication abnormality between M7030-PLC1 and PLC2
Electronic control abnormality
The solution for the communication abnormality between M7030-PLC1 and PLC2 would depend on the specific error and its underlying cause. Some possible solutions include checking the communication settings, diagnosing hardware issues, and ensuring that
KM-ASSYH2-07
192
M7031
[Later Section] M7031-Abnormal material on the clamping jaw during startup
Abnormal personnel operation
The answer to the error described as [Later Section] M7031-Abnormal material on the clamping jaw during startup depends on the root cause of the issue. Some possible solutions include cleaning the clamping jaw, replacing
KM-ASSYH2-07
193
M7032
[Later section] M7032-buffer area conveyor belt card abnormality
Organizational Abnormality
The M7032-buffer area conveyor belt card abnormality error occurs when the buffer area of a conveyor belt card experiences an issue with its communication with the control system. The typical solution is to reset the buffer area and perform
KM-ASSYH2-07
194
M7033
[Later section] M7033-Disconnected from upstream communication
Electronic control abnormality
This error message typically indicates that your device, such as a printer, camera, or scanner, is no longer connected to the communication channel upstream. The solution may involve checking for loose cables, resetting the device, updating drivers or firm
KM-ASSYH2-07
195
M7034
[Later Section] M7034-Abnormal conveyor belt card in work area
Organizational Abnormality
The solution for the error described as M7034-Abnormal conveyor belt card in work area depends on the specific cause of the problem. It could be that the card is damaged or dirty, or that there is a malfunction in
KM-ASSYH2-07
198
M7037
[Later section] M7037-Work area blocking cylinder abnormality
Machine cylinder abnormality
The solution for the M7037 work area blocking cylinder abnormality error involves locating and correcting the issue that is preventing a cylinder from functioning properly in the work area. This may include adjusting the parameters of the cyl
KM-ASSYH2-07
200
M7039
[Rear section] M7039-Abnormal positioning cylinder on the side of the work area
Machine cylinder abnormality
The solution to the Rear section M7039-Abnormal positioning cylinder on the side of the work area error is to adjust or reposition the cylinder so that it is properly aligned with the work area. This may involve
KM-ASSYH2-07
203
M7042
[Rear section] M7042-Width adjustment motor rear limit abnormality
Electronic control abnormality
The solution for the "Rear section M7042-Width adjustment motor rear limit abnormality" error typically involves adjusting the width of the rear section to ensure proper clearance between the vehicle body and the rear wheels. This
KM-ASSYH2-07
209
M7048
[Rear section] M7048-Left suction nozzle lift cylinder abnormality
Machine cylinder abnormality
The solution for the error described as "rear section M7048-Left suction nozzle lift cylinder abnormality" involves checking for leaks, damage, or worn parts in the lift cylinder and replacing or repair
KM-ASSYH2-07
211
M7050
[Rear section] M7050-Left lifting cylinder abnormality
Machine cylinder abnormality
The solution for the left lifting cylinder abnormality in the rear section of M7050 is to inspect the cylinder for leaks, damage, or incorrect pressure settings. Replacement of the cylinder might be necessary if it is
KM-ASSYH2-07
213
M7052
[Rear section] M7052-Right suction nozzle lifting cylinder abnormality
Machine cylinder abnormality
The solution for the M7052 error may involve troubleshooting and repairing the right suction nozzle lifting cylinder. It may involve checking for any leaks or blockages in the nozzle that could be causing
KM-ASSYH2-07
215
M7054
[Rear section] M7054-Right lifting cylinder abnormality
Machine cylinder abnormality
The solution for the error described as [Rear section] M7054-Right lifting cylinder abnormality may vary depending on the specific issue but usually involves checking the connections, pressure release valves, and replacing faulty parts.
KM-ASSYH2-07
218
M7057
[Rear section] M7057-The left suction nozzle is abnormal in vacuum suction
Electronic control abnormality
M7057 error in vacuum suction indicates abnormal behavior in the left suction nozzle of the rear section. To fix the error, inspect and clean or replace the nozzle as required.
KM-ASSYH2-07
219
M7058
[Rear section] M7058-Right suction nozzle vacuum abnormality
Electronic control abnormality
The solution for the error described as "Rear section" M7058-Right suction nozzle vacuum abnormality may involve checking for blockages or restrictions in the suction hose, inspecting the nozzle for
KM-ASSYH2-07
225
M7064
[Rear section] M7064-The upper jacking cylinder in the Tray area is abnormal
Machine cylinder abnormality
The solution for the error "Rear section M7064-The upper jacking cylinder in the Tray area is abnormal" would be to identify the cause of the abnormal condition and take corrective actions to repair or replace
KM-ASSYH2-07
227
M7066
[Rear section] M7066-The jacking cylinder at the lower level of the Tray area is abnormal
Machine cylinder abnormality
The solution for this error can vary depending on the specific details of the problem. However, one possibility could be to check if the cylinder oil is properly changed and if the jacking system is functioning optimally. If the issue is related to the
KM-ASSYH2-07
229
M7068
[Later section] M7068-The material cylinder entering the Tray section is abnormal
Machine cylinder abnormality
The solution for the error M7068 could be identifying and addressing the issue with the material cylinder, ensuring it meets the required specifications and is properly aligned with the Tray section. It may also involve updating the control software or adjust
KM-ASSYH2-07
1
M7000
[Previous section] M7000-Start to detect the presence of materials in the work area, please confirm the status of the work area
Abnormal personnel operation
The solution to the error M7000-Start to detect the presence of materials in the work area, please confirm the status of the work area is to ensure that the work area is clear and free of any materials. This will allow the
KM-ASSYH2-07
3
M7002
[Previous section] M7002 - Tray area full alarm
Abnormal personnel operation
The solution to the M7002 - Tray area full alarm error is to reduce the number of items on the tray by removing unnecessary items or reorganizing the tray layout. You can also use the "Clear All" option to clear
KM-ASSYH2-07
4
M7003
[Previous section] M7003-Incoming Tray area shortage alarm
Abnormal personnel operation
The solution for M7003-Incoming Tray area shortage alarm error in an office phone system seems to be clearing any obstructions or blockages on the incoming tray. If that does not resolve the issue, resetting the alarm
KM-ASSYH2-07
5
M7004
[Previous section] M7004-no material alarm in receiving Tray area
Abnormal personnel operation
The solution to the error described as M7004-no material alarm in receiving Tray area is likely to involve adjusting the material handling system and the alarm settings to ensure that alarms are triggered when materials are loaded into the tray area
KM-ASSYH2-07
6
M7005
[Previous paragraph] M7005 - Timeout exception waiting for the host computer to reply to the detection result
Machine communication abnormality
The solution for M7005 Timeout exception waiting for the host computer to reply to the detection result is to allow more time for the host computer to respond or check the network settings to ensure that there are no issues with the connection between the