MACHINE_NO
stringclasses
48 values
ERROR_ID
int64
1
999
ERROR_CODE
stringclasses
245 values
ERROR_DESC
stringlengths
14
179
ERROR_CATEGORY1
stringclasses
11 values
SOLUTION
stringlengths
40
290
KM-ASSYM1-01
41
M7040
M7040-The right blocking cylinder in the work area rises abnormally (X42), please check whether the cylinder is stuck when rising
Organizational Abnormality
The solution to the M7040-The right blocking cylinder in the work area rises abnormally (X42) error is to check if the cylinder is stuck when rising. If the cylinder is stuck, it
KM-ASSYM1-01
43
M7042
M7042-The jacking cylinder in the work area rises abnormally (X44), please check whether the cylinder is stuck when rising
Organizational Abnormality
The M7042 error occurs when the jacking cylinder in the work area rises abnormally. To resolve the error, check if the cylinder is stuck when it rises. If it is, try to release the cyl
KM-ASSYM1-01
44
M7043
M7043-The lifting cylinder in the work area is abnormally descending (X45), please check whether the cylinder is stuck when descending
Organizational Abnormality
The solution for the M7043 error is to check the lifting cylinder for any abnormalities and ensure that it is functioning properly. This may involve troubleshooting or disassembling and reassembling the cylinder depending on
KM-ASSYM1-01
50
M7049
M7049-The cylinder of the left glue cylinder in the slide area is abnormally descending (X54), please check whether the cylinder is stuck when descending
Organizational Abnormality
If you encounter the error M7049-The cylinder of the left glue cylinder in the slide area is abnormally descending (X54), it may indicate that the cylinder is stuck or has a problem with
KM-ASSYM1-01
51
M7050
M7050-The cylinder of the right glue cylinder in the slide area is rising abnormally (X55), please check whether the cylinder is stuck when rising
Organizational Abnormality
The M7050 error indicates that the right glue cylinder in the slide area is rising abnormally. To diagnose the issue, check whether the cylinder is stuck when rising. If it is, then the solution is to
KM-ASSYM1-01
53
M7052
M7052-The dispensing cylinder cylinder does not sense the upper limit before the slide area moves, please press the reset button first
Organizational Abnormality
The solution to M7052 error is to press the reset button before moving the slide area. This will restart the machine and allow the dispensing cylinder to sense the upper limit before dispensing. This will prevent the error from occurring again
KM-ASSYM1-01
54
M7053
M7053-The current glue amount is too much, please reduce it
Electronic control abnormality
Reduce the current glue amount by using less adhesive, replacing damaged parts, or adjusting the bonding process to ensure proper adhesion. In some cases, the use of a different type of adhesive or solvent may
KM-ASSYM1-01
55
M7054
M7054-The current dispensing amount is too small, please increase
Electronic control abnormality
The error M7054 usually occurs when the dispensing amount is less than the minimum amount required. To solve this error, you need to increase the dispensing amount by adjusting the settings on your printer or using a different ink cartr
KM-ASSYM1-01
65
M7064
M7064-X-axis servo NO readly(X15)&ERROR, please check whether the X-axis servo driver is abnormal
Electronic control abnormality
The solution for the error M7064-X-axis servo NO ready(X15)&ERROR could involve several steps. First, unplug and plug in the X-axis servo driver to check if the issue is with
KM-ASSYM1-01
67
M7066
M7066-X axis left limit is abnormal, far away from the origin end (X10), please check whether the slide table touches the limit
Electronic control abnormality
The solution for M7066-X axis left limit error is to verify whether the slide table is touching the limit. If it is touching the limit, adjust the limit switches to stop the slide table from touching. If it is not
KM-ASSYM1-01
68
M7067
M7067-X axis return to origin time has timed out, please check whether the slide table is abnormal or stuck
Electronic control abnormality
The error M7067 typically occurs when the X-axis slide table times out during its return to origin movement. This could be due to a malfunctioning actuator, a stuck slide table, or a problem with the home position
KM-ASSYM1-01
69
M7068
M7068-Y-axis servo NO readly(X16)&ERROR, please check whether the X-axis servo driver is abnormal
Electronic control abnormality
The solution for the error described as M7068-Y-axis servo NO readly(X16) &ERROR is to confirm whether the X-axis servo driver is functioning correctly. This can be done by using the
KM-ASSYM1-01
71
M7070
M7070-Y axis rear limit is abnormal, far away from the origin end (X12), please check whether the slide table touches the limit
Electronic control abnormality
There are a few possible solutions to address the error M7070-Y axis rear limit is abnormal, far away from the origin end (X12) including: 1. Adjusting the slide table position to ensure
KM-ASSYM1-01
72
M7071
M7071-Y axis return to origin time has timed out, please check whether the slide table is abnormal or stuck
Electronic control abnormality
The M7071-Y axis return to origin time has timed out error indicates that the Y-axis slide table is not responding to commands. This can be due to a stuck or abnormal condition. To troubleshoot this issue
KM-ASSYM1-01
73
M7072
M7072-Z-axis servo NO readly(X17)&ERROR, please check whether the Z-axis servo driver is abnormal
Electronic control abnormality
The error M7072-Z-axis servo NO readly(X17)&ERROR typically indicates an issue with the Z-axis servo driver circuitry. It is recommended to first check for wiring errors or loose connections
KM-ASSYM1-01
75
M7074
M7074-Z axis lower limit abnormality, far away from the origin end (X14), please check whether the slide table touches the limit
Electronic control abnormality
The solution for the error M7074 due to the lower limit abnormality of the Z-axis, far away from the origin end (X14), is to ensure that the slide table does not touch the limit. This can
KM-ASSYM1-01
76
M7075
M7075-Z axis return to origin time has timed out, please check whether the slide table is abnormal or stuck
Electronic control abnormality
To resolve the M7075 error where the Z axis return to origin has timed out, make sure to check the slide table abnormality or sticking condition. If it is normal, the problem may be with the encoder or the
KM-ASSYM1-01
82
M7081
M7081-Timeout waiting for MARK point in place signal
Electronic control abnormality
This issue is often resolved by adjusting the default timeout value for the place signal waiting period in the configuration settings. You can either increase the timeout value or try implementing the "force Mark" button in the Mark dialog. If the issue persists,
KM-ASSYH4-07
161
M7000
[Later Section] M7000-Start to detect the presence of materials in the work area, please confirm the status of the work area
Abnormal personnel operation
The solution for the error described as [Later Section] M7000-Start is to confirm the status of the work area. This can be achieved by manually scanning the area using the device's sensor or by using software to
KM-ASSYH4-07
180
M7019
[Second paragraph] M7019-The device has not returned to the origin, please execute the device to return to the origin first
Abnormal personnel operation
The solution to the error M7019 "The device has not returned to the origin, please execute the device to return to the origin first?" is to follow the instructions provided on the device, which might include pressing a button or entering a
KM-ASSYH4-07
182
M7021
[Later Section] M7021-Product abnormality when starting secondary positioning
Abnormal personnel operation
The solution to the error described in M7021-Product abnormality when starting secondary positioning is to ensure that the product is positioned correctly and not obstructed. Additionally, the operator should verify that all safety features are functioning properly
KM-ASSYH4-07
189
M7028
[Later section] M7028-Safety door opens abnormally during return to origin
Abnormal personnel operation
The solution for the error described as M7028-Safety door opens abnormally during return to origin requires an inspection of the safety door drive system for any damage or malfunction. The door may need to be adjusted or replaced
KM-ASSYM1-01
83
M7082
M7082-MARK point recognition failed
Visual abnormality
The solution for the M7082-MARK point recognition failed error is to reset the device's memory and perform the point recognition process again. If the issue persists, it may be necessary to consult the device's manual or contact
KM-ASSYM1-01
84
M7083
M7083-CCD timed out waiting for PLC completion signal (please check D720=1)
Electronic control abnormality
The solution for the M7083-CCD timed out waiting for PLC completion signal error is to check that the D720=1 parameter is set correctly in the communication configuration of the PLC. If the parameter is
KM-ASSYM1-01
85
M7084
M7084-Scan code NG
Electronic control abnormality
The M7084-Scan code NG error often indicates a connectivity issue between the scanner and the computer or printer. A possible solution is to check the connections, restart the devices, and update device drivers. If the issue pers
KM-ASSYM1-01
86
M7085
M7085-TE reply card station Fail
Kazam exception
The solution for the error described as M7085-TE may vary depending on the specific issue and configuration of the system. It could involve resetting or updating the reply card station, checking for communication issues, or consulting the system documentation for
KM-ASSYM1-01
87
M7086
M7086-Scan code OK and receive TE Read signal timeout
Kazam exception
This error typically occurs when there is no data available on the USB port. It could be due to a problem with the computer's USB interface or a malfunctioning printer. To resolve the issue, you may need to try restarting your computer
KM-ASSYM1-01
88
M7087
M7087-TE LINK out of range
Kazam exception
The error M7087-TE LINK out of range typically occurs when the TTL setting of a router or access point is too low. To resolve this issue, you can increase the TTL setting on the router or access point,
KM-ASSYM1-01
89
M7088
M7088-TE LINK timeout
Kazam exception
The solution for the error described as M7088-TE LINK timeout involves checking the network connection, verifying the routing settings, and restarting the network or server.
KM-ASSYM1-01
90
M7089
M7089-The dispensing area detected by the upper camera is out of range
Visual abnormality
The solution for the M7089 error is to adjust the location and orientation of the upper camera to ensure it is within range of the dispensing area. If the camera cannot be moved, the error can also be resolved by adjusting the
KM-ASSYM1-01
91
M7090
M7090-PLC timed out waiting for the host computer to transmit the MARK point identification signal
Visual abnormality
The M7090-PLC error occurs when the host computer fails to transmit the MARK point identification signal within the specified timeline. To resolve this issue, first confirm that the host computer is correctly configured and sends the signal within the
KM-ASSYM1-01
92
M7091
M7091-PLC timed out waiting for the host computer to transmit the dispensing point position
Visual abnormality
The solution for M7091-PLC time-out error is to ensure that the host computer is transmitting dispensing point position information to the PLC. The issue could also be caused by communication between the two devices being disabled or
KM-ASSYM1-01
93
M7092
M7092-PLC timed out while waiting for the area identification completion signal from the host computer
Visual abnormality
The solution for the M7092-PLC timed out error involving area identification completion signal from the host computer could be to reduce the timeout value in the PLC configuration, check for network connectivity issues or congestion, or
KM-ASSYM1-01
94
M7093
M7093-PLC timed out waiting for the host computer to send the scan code result
Machine communication abnormality
The solution for the error described as M7093-PLC timed out waiting for the host computer to send the scan code result is to ensure that the host computer is properly connected and responsive, and that the PLC settings are
KM-ASSYM1-01
95
M7094
M7094-PLC timed out waiting for the signal from the host computer to complete the electronic scale clearing
Visual abnormality
M7094-PLC timed out waiting for the signal from the host computer to complete the electronic scale clearing can be resolved by checking if the host computer is properly connected and also ensuring that there are no delays or issues with the
KM-ASSYM1-01
96
M7095
M7095-PLC timed out waiting for the host computer to transmit the weighing result
Machine communication abnormality
The solution for M7095-PLC timed out waiting for the host computer to transmit the weighing result can be resolved by checking the communication settings in the PLC and making sure they are correct, resetting the PLC and
KM-ASSYM1-03
6
M7007
Alarm: pressing position blocked_sensor double lights
Organizational Abnormality
There are several possible causes for this error, including a malfunctioning light sensor or an issue with the camera. However, the most common solution is to clean the affected area thoroughly and try again. If the problem persists, contact the manufacturer or
KM-ASSYM1-03
8
M7009
Alarm: pad pushes out cylinder 1_moving position alarm
Organizational Abnormality
The solution for the "pad pushes out cylinder 1_moving position alarm" error would likely involve checking the wiring and making sure that the pad and cylinder are properly aligned. It is recommended to contact a professional mechanic if
KM-ASSYM1-03
32
M7044
Alarm: During initialization, the assembly line materials were not cleared.
Abnormal personnel operation
To resolve the "Alarm: During initialization, the assembly line materials were not cleared." error, ensure that all materials are properly placed and cleared from the assembly line before beginning operations. This can prevent any potential issues during the initial setup of the production
KM-ASSYM1-03
33
M7045
Alarm: initial startup, there is material in the assembly line
Abnormal personnel operation
To fix the error described as Alarm: initial startup, there is material in the assembly line, you'll need to identify the source of the material and clear it from the assembly line. This may require adjusting your manufacturing processes or stopping production
KM-ASSYM1-05
1
M7000
M7000-The glue bucket is about to be used up, please prepare to fill the glue bucket
Abnormal personnel operation
The solution to the M7000 error message "The glue bucket is about to be used up, please prepare to fill the glue bucket" is to refill the empty glue bucket before it runs out of glue. This
KM-ASSYM1-05
2
M7001
M7001-Start detecting that there is material in the work area, please select the work area status
Abnormal personnel operation
The solution for the error "M7001-Start detecting that there is material in the work area, please select the work area status?" is to ensure that the appropriate work area is selected before starting the processing by either re-routing
KM-ASSYM1-05
7
M7006
M7006-1 point detection failed
Visual abnormality
The solution for the M7006-1 error "point detection failed" cannot be provided without additional information about the underlying cause. This error occurs when the device fails to detect a point or location. It could be due to various reasons such
KM-ASSYM1-05
8
M7007
M7007-2 point detection failed
Visual abnormality
The solution for the M7007-2 point detection failed error typically involves resetting the camera or device, updating driver software, or contacting technical support for further assistance.
KM-ASSYM1-05
9
M7008
M7008-3 point detection failed
Visual abnormality
The M7008-3 point detection failed error is typically caused by issues with the camera or computer hardware, improper software installation or settings, or insufficient light conditions. The solution may include checking for hardware malfunctions, updating software and
KM-ASSYM1-05
10
M7009
M7009-4 point detection failed
Visual abnormality
The solution for the error "M7009-4 point detection failed" typically involves checking the camera's settings, performing a calibration, and updating any necessary software. If the issue persists, it may require technical support from the
KM-ASSYM1-05
11
M7010
M7010-5 point detection failed
Visual abnormality
The M7010-5 point detection failed error typically occurs when the device's camera is unable to detect points due to poor lighting conditions, camera focus, or hardware problems. To resolve this issue, try cleaning the camera lens, adjust
KM-ASSYM1-05
12
M7011
M7011-6 point detection failed
Visual abnormality
The M7011-6 error occurs when the camera is unable to accurately detect points in the field of view. Possible causes of this error include poor lighting conditions, camera shake or movement, incorrect lens settings, or a dirty or damaged
KM-ASSYM1-05
13
M7012
M7012-7 point detection failed
Visual abnormality
M7012-7 error occurs when the camera cannot detect any point on an object during image processing. This can be due to poor image quality or lighting conditions. A possible solution is to adjust the camera parameters, such as focus or bright
KM-ASSYM1-05
14
M7013
M7013-8 point detection failed
Visual abnormality
M7013-8 point detection failed error can occur in AutoCAD when the program is unable to detect points accurately. One potential solution is to increase the accuracy of the point detection settings or to use a different type of point detection algorithm
KM-ASSYM1-05
15
M7014
M7014-9 point detection failed
Visual abnormality
The solution for error M7014-9 is to check the image quality, ensure the object is visible, and review the settings in the object detection algorithm. If necessary, you may need to adjust the object detection parameters, increase the object
KM-ASSYM1-05
16
M7015
M7015-10 point detection failed
Visual abnormality
The solution for M7015-10 error, point detection failed, may refer to re-enabling point detection in the camera's settings, correcting the camera's focus and resolution, or updating the camera driver. In
KM-ASSYM1-05
17
M7016
M7016-Emergency stop&&safety door is open, please check the safety door and emergency stop switch (X30)
Abnormal personnel operation
The solution for the M7016-Emergency stop&& safety door is open error is to check the safety door and emergency stop switch (X30). Make sure that the safety door is closed and the emergency stop switch is turned
KM-ASSYM1-05
18
M7017
M7017-The device model setting has not been set, please set the device model
Abnormal personnel operation
To fix the M7017 error, you need to set the device model on your Amazon App Store account. This can be done by following the steps in the Amazon Developer Console:
KM-ASSYM1-05
19
M7018
M7018-The automatic process is not reset before starting, please press the reset button first
Abnormal personnel operation
The solution to the M7018 error is to press the reset button first before attempting to start the automatic process. Once the reset is complete, the process should restart without any issues.
KM-ASSYM1-05
20
M7019
M7019-The device has not returned to the origin, please execute the device to return to the origin first
Abnormal personnel operation
The solution to the M7019 error is to first execute the device to return to its origin before attempting any further actions. This error occurs when a device is not properly synchronized with its origin, and it requires the device to be returned to
KM-ASSYM1-05
38
M7037
M7037-The discharging operation of the rear buffer conveyor belt times out, please check whether there is any jamming between the upper and lower reaches of the machine
Organizational Abnormality
M7037 error occurs when the discharging operation of the rear buffer conveyor belt times out and there is jamming between the upper and lower reaches of the machine. The solution is to clear any jamming in the machine, ensuring
KM-ASSYM1-05
41
M7040
M7040-The right blocking cylinder in the work area rises abnormally (X42), please check whether the cylinder is stuck when rising
Organizational Abnormality
The solution to the M7040-The right blocking cylinder in the work area rises abnormally (X42) error is to check if the cylinder is stuck when rising. If the cylinder is stuck, it
KM-ASSYM1-05
44
M7043
M7043-The lifting cylinder in the work area is abnormally descending (X45), please check whether the cylinder is stuck when descending
Organizational Abnormality
The solution for the M7043 error is to check the lifting cylinder for any abnormalities and ensure that it is functioning properly. This may involve troubleshooting or disassembling and reassembling the cylinder depending on
KM-ASSYM1-05
51
M7050
M7050-The cylinder of the right glue cylinder in the slide area is rising abnormally (X55), please check whether the cylinder is stuck when rising
Organizational Abnormality
The M7050 error indicates that the right glue cylinder in the slide area is rising abnormally. To diagnose the issue, check whether the cylinder is stuck when rising. If it is, then the solution is to
KM-ASSYM1-05
65
M7064
M7064-X-axis servo NO readly(X15)&ERROR, please check whether the X-axis servo driver is abnormal
Electronic control abnormality
The solution for the error M7064-X-axis servo NO ready(X15)&ERROR could involve several steps. First, unplug and plug in the X-axis servo driver to check if the issue is with
KM-ASSYM1-05
68
M7067
M7067-X axis return to origin time has timed out, please check whether the slide table is abnormal or stuck
Electronic control abnormality
The error M7067 typically occurs when the X-axis slide table times out during its return to origin movement. This could be due to a malfunctioning actuator, a stuck slide table, or a problem with the home position
KM-ASSYM1-05
71
M7070
M7070-Y axis rear limit is abnormal, far away from the origin end (X12), please check whether the slide table touches the limit
Electronic control abnormality
There are a few possible solutions to address the error M7070-Y axis rear limit is abnormal, far away from the origin end (X12) including: 1. Adjusting the slide table position to ensure
KM-ASSYM1-05
74
M7073
M7073-The limit on the Z axis is abnormal, close to the origin end (X13), please check whether the slide table touches the limit
Electronic control abnormality
The solution to M7073 error that states the limit on the Z axis is abnormal, close to the origin end (X13) is to check whether the slide table touches the limit. This can be accomplished by physically inspecting
KM-ASSYM1-05
90
M7089
M7089-The dispensing area detected by the upper camera is out of range
Visual abnormality
The solution for the M7089 error is to adjust the location and orientation of the upper camera to ensure it is within range of the dispensing area. If the camera cannot be moved, the error can also be resolved by adjusting the
KM-ASSYM1-05
94
M7093
M7093-PLC timed out waiting for the host computer to send the scan code result
Machine communication abnormality
The solution for the error described as M7093-PLC timed out waiting for the host computer to send the scan code result is to ensure that the host computer is properly connected and responsive, and that the PLC settings are
KM-ASSYM1-05
99
M7098
M7098-The current position of the PCB board exceeds the safe distance, please check whether the PC board is placed properly
Other exceptions
The solution to M7098 error is to check whether the PCB board is placed correctly and not exceeding the safe distance. The board should be centered properly and securely fastened to prevent any damage to the components or the board itself
KM-ASSYM1-05
102
M7101
M7101-Please clean the scale pan and press the "Scale Pan Easy Clean Button"
Abnormal personnel operation
The solution for the error M7101 is to clean the scale pan using a cleaning tool provided by the scale manufacturer, and then to press the "Scale Pan Easy Clean Button" to reset the scale. If the problem persists, the
KM-ASSYM1-05
113
M7112
M7112-Visual software model number is inconsistent with PLC model number
Visual abnormality
The solution to the M7112 error is to check that the visual software model number matches the PLC model number. If both numbers are correct, then the error may be caused by a mismatch between the cable connections, power supply,
KM-ASSYM1-05
21
M7020
There is no code scanner in the work area of ??M7020-T surface, so self-inspection cannot be e done in the work area. Please put the undispensed plate in the front buffer to start
Abnormal personnel operation
The solution for this error is to move the undispensed plate from the work area to the front buffer so that it can be properly scanned for self-inspection. This will allow the code scanner to function properly and prevent further errors from
KM-ASSYM1-05
33
M7032
M7032-The feeding operation of the front Buffer conveyor belt times out, please check whether there is any jamming between the upper and lower reaches of the machine
Organizational Abnormality
The error M7032 indicates that the feeding operation of the front buffer conveyor belt has timed out, which may be due to jamming between the upper and lower reaches of the machine. The solution to this issue is to check for
KM-ASSYM1-05
34
M7033
M7033-The discharging operation of the front Buffer conveyor belt has timed out. Please check whether there is a jam between the front Buffer and the work area in the machine.
Organizational Abnormality
The solution for the M7033 error described as "Discharging operation of the front Buffer conveyor belt has timed out" is to check for any jam or obstruction between the front Buffer and the work area in the machine
KM-ASSYM1-05
35
M7034
M7034-The feeding operation of the conveyor belt in the work area has timed out, please check whether the machine is jammed
Organizational Abnormality
The M7034 error message indicates that the conveyor belt feeding operation has timed out. To resolve this issue, first, check if the machine is jammed. Clear any blockages or jams from the conveyor belt. If
KM-ASSYM1-05
36
M7035
M7035-The discharging operation of the conveyor belt in the work area has timed out, please check whether the machine is jammed
Organizational Abnormality
The solution for error M7035 is to manually check the conveyor belt for any jams or obstructions. If the belt is jammed, clear the obstruction and restart the machine.
KM-ASSYM1-05
37
M7036
M7036-The feeding operation of the rear Buffer conveyor belt has timed out. Please check whether there is any jamming between the machine work area and the rear Buffer
Organizational Abnormality
The solution for the M7036 error is to check if there is any jamming between the machine work area and the rear Buffer, and to clear any blockages that are detected if possible. If the blockage cannot be cleared, then
KM-ASSYM1-05
39
M7038
M7038-The left blocking cylinder in the work area rises abnormally (X40), please check whether the cylinder is stuck when rising
Organizational Abnormality
The solution for the M7038-The left blocking cylinder in the work area rises abnormally (X40) error is to check if the cylinder is stuck when rising. If the cylinder is stuck, you
KM-ASSYM1-05
40
M7039
M7039-The left blocking cylinder in the work area is abnormally descending (X41), please check whether the cylinder is stuck when descending
Organizational Abnormality
The error message M7039-The left blocking cylinder in the work area is abnormally descending (X41), please check whether the cylinder is stuck when descending indicates that there is an issue on a cylinder
KM-ASSYM1-05
42
M7041
M7041-The right blocking cylinder in the work area is abnormally descending (X43), please check whether the cylinder is stuck when descending
Organizational Abnormality
The M7041 error message indicates that the right blocking cylinder is descending abnormally and could be stuck. The solution is to check the cylinder for possible mechanical or electrical issues, such as worn or damaged seals, fault
KM-ASSYM1-05
43
M7042
M7042-The jacking cylinder in the work area rises abnormally (X44), please check whether the cylinder is stuck when rising
Organizational Abnormality
The M7042 error occurs when the jacking cylinder in the work area rises abnormally. To resolve the error, check if the cylinder is stuck when it rises. If it is, try to release the cyl
KM-ASSYM1-05
49
M7048
M7048-The cylinder of the left glue cylinder in the slide area is rising abnormally (X50), please check whether the cylinder is stuck when rising
Organizational Abnormality
If the left glue cylinder in the slide area is rising abnormally and showing error code M7048, it's possible that the cylinder is stuck. To resolve this issue, you can try applying a gentle pressure on
KM-ASSYM1-05
50
M7049
M7049-The cylinder of the left glue cylinder in the slide area is abnormally descending (X54), please check whether the cylinder is stuck when descending
Organizational Abnormality
If you encounter the error M7049-The cylinder of the left glue cylinder in the slide area is abnormally descending (X54), it may indicate that the cylinder is stuck or has a problem with
KM-ASSYM1-05
52
M7051
M7051-The cylinder of the right glue cylinder in the slide area is abnormally descending (X61), please check whether the cylinder is stuck when descending
Organizational Abnormality
The M7051 error message indicates that the cylinder in the slide area is descending abnormally. This issue could be caused by the cylinder becoming stuck while descending. To resolve this, check the cylinder for any block
KM-ASSYM1-05
53
M7052
M7052-The dispensing cylinder cylinder does not sense the upper limit before the slide area moves, please press the reset button first
Organizational Abnormality
The solution to M7052 error is to press the reset button before moving the slide area. This will restart the machine and allow the dispensing cylinder to sense the upper limit before dispensing. This will prevent the error from occurring again
KM-ASSYM1-05
54
M7053
M7053-The current glue amount is too much, please reduce it
Electronic control abnormality
Reduce the current glue amount by using less adhesive, replacing damaged parts, or adjusting the bonding process to ensure proper adhesion. In some cases, the use of a different type of adhesive or solvent may
KM-ASSYM1-05
55
M7054
M7054-The current dispensing amount is too small, please increase
Electronic control abnormality
The error M7054 usually occurs when the dispensing amount is less than the minimum amount required. To solve this error, you need to increase the dispensing amount by adjusting the settings on your printer or using a different ink cartr
KM-ASSYM1-05
66
M7065
M7065-The right limit of the X-axis is abnormal, close to the origin end (X7), please check whether the slide table touches the limit
Electronic control abnormality
The solution for the M7065 error is to check if the slide table is touching the limit at the origin end (X7) and increase the left limit value if necessary to prevent the issue.
KM-ASSYM1-05
67
M7066
M7066-X axis left limit is abnormal, far away from the origin end (X10), please check whether the slide table touches the limit
Electronic control abnormality
The solution for M7066-X axis left limit error is to verify whether the slide table is touching the limit. If it is touching the limit, adjust the limit switches to stop the slide table from touching. If it is not
KM-ASSYM1-05
69
M7068
M7068-Y-axis servo NO readly(X16)&ERROR, please check whether the X-axis servo driver is abnormal
Electronic control abnormality
The solution for the error described as M7068-Y-axis servo NO readly(X16) &ERROR is to confirm whether the X-axis servo driver is functioning correctly. This can be done by using the
KM-ASSYM1-05
70
M7069
M7069-Y axis front limit is abnormal, close to the origin end (X11), please check whether the slide table touches the limit
Electronic control abnormality
The solution for M7069-Y axis front limit is abnormal, close to the origin end (X11) is to check whether the slide table touches the limit. The problem could be caused by the slide table moving too far
KM-ASSYM1-05
72
M7071
M7071-Y axis return to origin time has timed out, please check whether the slide table is abnormal or stuck
Electronic control abnormality
The M7071-Y axis return to origin time has timed out error indicates that the Y-axis slide table is not responding to commands. This can be due to a stuck or abnormal condition. To troubleshoot this issue
KM-ASSYM1-05
73
M7072
M7072-Z-axis servo NO readly(X17)&ERROR, please check whether the Z-axis servo driver is abnormal
Electronic control abnormality
The error M7072-Z-axis servo NO readly(X17)&ERROR typically indicates an issue with the Z-axis servo driver circuitry. It is recommended to first check for wiring errors or loose connections
KM-ASSYM1-05
75
M7074
M7074-Z axis lower limit abnormality, far away from the origin end (X14), please check whether the slide table touches the limit
Electronic control abnormality
The solution for the error M7074 due to the lower limit abnormality of the Z-axis, far away from the origin end (X14), is to ensure that the slide table does not touch the limit. This can
KM-ASSYM1-05
76
M7075
M7075-Z axis return to origin time has timed out, please check whether the slide table is abnormal or stuck
Electronic control abnormality
To resolve the M7075 error where the Z axis return to origin has timed out, make sure to check the slide table abnormality or sticking condition. If it is normal, the problem may be with the encoder or the
KM-ASSYM1-05
81
M7080
M7080-Camera acquisition failed
Visual abnormality
The M7080-Camera acquisition failed error occurs when the camera is unable to acquire a clear image due to poor lighting conditions, distortion in the lens, or incorrect settings. To resolve this issue, first reset the camera and then check
KM-ASSYM1-05
82
M7081
M7081-Timeout waiting for MARK point in place signal
Electronic control abnormality
This issue is often resolved by adjusting the default timeout value for the place signal waiting period in the configuration settings. You can either increase the timeout value or try implementing the "force Mark" button in the Mark dialog. If the issue persists,
KM-ASSYM1-05
83
M7082
M7082-MARK point recognition failed
Visual abnormality
The solution for the M7082-MARK point recognition failed error is to reset the device's memory and perform the point recognition process again. If the issue persists, it may be necessary to consult the device's manual or contact
KM-ASSYM1-05
84
M7083
M7083-CCD timed out waiting for PLC completion signal (please check D720=1)
Electronic control abnormality
The solution for the M7083-CCD timed out waiting for PLC completion signal error is to check that the D720=1 parameter is set correctly in the communication configuration of the PLC. If the parameter is
KM-ASSYM1-05
85
M7084
M7084-Scan code NG
Electronic control abnormality
The M7084-Scan code NG error often indicates a connectivity issue between the scanner and the computer or printer. A possible solution is to check the connections, restart the devices, and update device drivers. If the issue pers
KM-ASSYM1-05
86
M7085
M7085-TE reply card station Fail
Kazam exception
The solution for the error described as M7085-TE may vary depending on the specific issue and configuration of the system. It could involve resetting or updating the reply card station, checking for communication issues, or consulting the system documentation for
KM-ASSYM1-05
87
M7086
M7086-Scan code OK and receive TE Read signal timeout
Kazam exception
This error typically occurs when there is no data available on the USB port. It could be due to a problem with the computer's USB interface or a malfunctioning printer. To resolve the issue, you may need to try restarting your computer