KM-ASSYM1-01 | 41 | M7040 | M7040-The right blocking cylinder in the work area rises abnormally (X42), please check whether the cylinder is stuck when rising | Organizational Abnormality | The solution to the M7040-The right blocking cylinder in the work area rises abnormally (X42) error is to check if the cylinder is stuck when rising. If the cylinder is stuck, it |
KM-ASSYM1-01 | 43 | M7042 | M7042-The jacking cylinder in the work area rises abnormally (X44), please check whether the cylinder is stuck when rising | Organizational Abnormality | The M7042 error occurs when the jacking cylinder in the work area rises abnormally. To resolve the error, check if the cylinder is stuck when it rises. If it is, try to release the cyl |
KM-ASSYM1-01 | 44 | M7043 | M7043-The lifting cylinder in the work area is abnormally descending (X45), please check whether the cylinder is stuck when descending | Organizational Abnormality | The solution for the M7043 error is to check the lifting cylinder for any abnormalities and ensure that it is functioning properly. This may involve troubleshooting or disassembling and reassembling the cylinder depending on |
KM-ASSYM1-01 | 50 | M7049 | M7049-The cylinder of the left glue cylinder in the slide area is abnormally descending (X54), please check whether the cylinder is stuck when descending | Organizational Abnormality | If you encounter the error M7049-The cylinder of the left glue cylinder in the slide area is abnormally descending (X54), it may indicate that the cylinder is stuck or has a problem with |
KM-ASSYM1-01 | 51 | M7050 | M7050-The cylinder of the right glue cylinder in the slide area is rising abnormally (X55), please check whether the cylinder is stuck when rising | Organizational Abnormality | The M7050 error indicates that the right glue cylinder in the slide area is rising abnormally. To diagnose the issue, check whether the cylinder is stuck when rising. If it is, then the solution is to |
KM-ASSYM1-01 | 53 | M7052 | M7052-The dispensing cylinder cylinder does not sense the upper limit before the slide area moves, please press the reset button first | Organizational Abnormality | The solution to M7052 error is to press the reset button before moving the slide area. This will restart the machine and allow the dispensing cylinder to sense the upper limit before dispensing. This will prevent the error from occurring again |
KM-ASSYM1-01 | 54 | M7053 | M7053-The current glue amount is too much, please reduce it | Electronic control abnormality | Reduce the current glue amount by using less adhesive, replacing damaged parts, or adjusting the bonding process to ensure proper adhesion. In some cases, the use of a different type of adhesive or solvent may |
KM-ASSYM1-01 | 55 | M7054 | M7054-The current dispensing amount is too small, please increase | Electronic control abnormality | The error M7054 usually occurs when the dispensing amount is less than the minimum amount required. To solve this error, you need to increase the dispensing amount by adjusting the settings on your printer or using a different ink cartr |
KM-ASSYM1-01 | 65 | M7064 | M7064-X-axis servo NO readly(X15)&ERROR, please check whether the X-axis servo driver is abnormal | Electronic control abnormality | The solution for the error M7064-X-axis servo NO ready(X15)&ERROR could involve several steps. First, unplug and plug in the X-axis servo driver to check if the issue is with |
KM-ASSYM1-01 | 67 | M7066 | M7066-X axis left limit is abnormal, far away from the origin end (X10), please check whether the slide table touches the limit | Electronic control abnormality | The solution for M7066-X axis left limit error is to verify whether the slide table is touching the limit. If it is touching the limit, adjust the limit switches to stop the slide table from touching. If it is not |
KM-ASSYM1-01 | 68 | M7067 | M7067-X axis return to origin time has timed out, please check whether the slide table is abnormal or stuck | Electronic control abnormality | The error M7067 typically occurs when the X-axis slide table times out during its return to origin movement. This could be due to a malfunctioning actuator, a stuck slide table, or a problem with the home position |
KM-ASSYM1-01 | 69 | M7068 | M7068-Y-axis servo NO readly(X16)&ERROR, please check whether the X-axis servo driver is abnormal | Electronic control abnormality | The solution for the error described as M7068-Y-axis servo NO readly(X16) &ERROR is to confirm whether the X-axis servo driver is functioning correctly. This can be done by using the |
KM-ASSYM1-01 | 71 | M7070 | M7070-Y axis rear limit is abnormal, far away from the origin end (X12), please check whether the slide table touches the limit | Electronic control abnormality | There are a few possible solutions to address the error M7070-Y axis rear limit is abnormal, far away from the origin end (X12) including:
1. Adjusting the slide table position to ensure |
KM-ASSYM1-01 | 72 | M7071 | M7071-Y axis return to origin time has timed out, please check whether the slide table is abnormal or stuck | Electronic control abnormality | The M7071-Y axis return to origin time has timed out error indicates that the Y-axis slide table is not responding to commands. This can be due to a stuck or abnormal condition. To troubleshoot this issue |
KM-ASSYM1-01 | 73 | M7072 | M7072-Z-axis servo NO readly(X17)&ERROR, please check whether the Z-axis servo driver is abnormal | Electronic control abnormality | The error M7072-Z-axis servo NO readly(X17)&ERROR typically indicates an issue with the Z-axis servo driver circuitry. It is recommended to first check for wiring errors or loose connections |
KM-ASSYM1-01 | 75 | M7074 | M7074-Z axis lower limit abnormality, far away from the origin end (X14), please check whether the slide table touches the limit | Electronic control abnormality | The solution for the error M7074 due to the lower limit abnormality of the Z-axis, far away from the origin end (X14), is to ensure that the slide table does not touch the limit. This can |
KM-ASSYM1-01 | 76 | M7075 | M7075-Z axis return to origin time has timed out, please check whether the slide table is abnormal or stuck | Electronic control abnormality | To resolve the M7075 error where the Z axis return to origin has timed out, make sure to check the slide table abnormality or sticking condition. If it is normal, the problem may be with the encoder or the |
KM-ASSYM1-01 | 82 | M7081 | M7081-Timeout waiting for MARK point in place signal | Electronic control abnormality | This issue is often resolved by adjusting the default timeout value for the place signal waiting period in the configuration settings. You can either increase the timeout value or try implementing the "force Mark" button in the Mark dialog. If the issue persists, |
KM-ASSYH4-07 | 161 | M7000 | [Later Section] M7000-Start to detect the presence of materials in the work area, please confirm the status of the work area | Abnormal personnel operation | The solution for the error described as [Later Section] M7000-Start is to confirm the status of the work area. This can be achieved by manually scanning the area using the device's sensor or by using software to |
KM-ASSYH4-07 | 180 | M7019 | [Second paragraph] M7019-The device has not returned to the origin, please execute the device to return to the origin first | Abnormal personnel operation | The solution to the error M7019 "The device has not returned to the origin, please execute the device to return to the origin first?" is to follow the instructions provided on the device, which might include pressing a button or entering a |
KM-ASSYH4-07 | 182 | M7021 | [Later Section] M7021-Product abnormality when starting secondary positioning | Abnormal personnel operation | The solution to the error described in M7021-Product abnormality when starting secondary positioning is to ensure that the product is positioned correctly and not obstructed. Additionally, the operator should verify that all safety features are functioning properly |
KM-ASSYH4-07 | 189 | M7028 | [Later section] M7028-Safety door opens abnormally during return to origin | Abnormal personnel operation | The solution for the error described as M7028-Safety door opens abnormally during return to origin requires an inspection of the safety door drive system for any damage or malfunction. The door may need to be adjusted or replaced |
KM-ASSYM1-01 | 83 | M7082 | M7082-MARK point recognition failed | Visual abnormality | The solution for the M7082-MARK point recognition failed error is to reset the device's memory and perform the point recognition process again. If the issue persists, it may be necessary to consult the device's manual or contact |
KM-ASSYM1-01 | 84 | M7083 | M7083-CCD timed out waiting for PLC completion signal (please check D720=1) | Electronic control abnormality | The solution for the M7083-CCD timed out waiting for PLC completion signal error is to check that the D720=1 parameter is set correctly in the communication configuration of the PLC. If the parameter is |
KM-ASSYM1-01 | 85 | M7084 | M7084-Scan code NG | Electronic control abnormality | The M7084-Scan code NG error often indicates a connectivity issue between the scanner and the computer or printer. A possible solution is to check the connections, restart the devices, and update device drivers. If the issue pers |
KM-ASSYM1-01 | 86 | M7085 | M7085-TE reply card station Fail | Kazam exception | The solution for the error described as M7085-TE may vary depending on the specific issue and configuration of the system. It could involve resetting or updating the reply card station, checking for communication issues, or consulting the system documentation for |
KM-ASSYM1-01 | 87 | M7086 | M7086-Scan code OK and receive TE Read signal timeout | Kazam exception | This error typically occurs when there is no data available on the USB port. It could be due to a problem with the computer's USB interface or a malfunctioning printer. To resolve the issue, you may need to try restarting your computer |
KM-ASSYM1-01 | 88 | M7087 | M7087-TE LINK out of range | Kazam exception | The error M7087-TE LINK out of range typically occurs when the TTL setting of a router or access point is too low. To resolve this issue, you can increase the TTL setting on the router or access point, |
KM-ASSYM1-01 | 89 | M7088 | M7088-TE LINK timeout | Kazam exception | The solution for the error described as M7088-TE LINK timeout involves checking the network connection, verifying the routing settings, and restarting the network or server. |
KM-ASSYM1-01 | 90 | M7089 | M7089-The dispensing area detected by the upper camera is out of range | Visual abnormality | The solution for the M7089 error is to adjust the location and orientation of the upper camera to ensure it is within range of the dispensing area. If the camera cannot be moved, the error can also be resolved by adjusting the |
KM-ASSYM1-01 | 91 | M7090 | M7090-PLC timed out waiting for the host computer to transmit the MARK point identification signal | Visual abnormality | The M7090-PLC error occurs when the host computer fails to transmit the MARK point identification signal within the specified timeline. To resolve this issue, first confirm that the host computer is correctly configured and sends the signal within the |
KM-ASSYM1-01 | 92 | M7091 | M7091-PLC timed out waiting for the host computer to transmit the dispensing point position | Visual abnormality | The solution for M7091-PLC time-out error is to ensure that the host computer is transmitting dispensing point position information to the PLC. The issue could also be caused by communication between the two devices being disabled or |
KM-ASSYM1-01 | 93 | M7092 | M7092-PLC timed out while waiting for the area identification completion signal from the host computer | Visual abnormality | The solution for the M7092-PLC timed out error involving area identification completion signal from the host computer could be to reduce the timeout value in the PLC configuration, check for network connectivity issues or congestion, or |
KM-ASSYM1-01 | 94 | M7093 | M7093-PLC timed out waiting for the host computer to send the scan code result | Machine communication abnormality | The solution for the error described as M7093-PLC timed out waiting for the host computer to send the scan code result is to ensure that the host computer is properly connected and responsive, and that the PLC settings are |
KM-ASSYM1-01 | 95 | M7094 | M7094-PLC timed out waiting for the signal from the host computer to complete the electronic scale clearing | Visual abnormality | M7094-PLC timed out waiting for the signal from the host computer to complete the electronic scale clearing can be resolved by checking if the host computer is properly connected and also ensuring that there are no delays or issues with the |
KM-ASSYM1-01 | 96 | M7095 | M7095-PLC timed out waiting for the host computer to transmit the weighing result | Machine communication abnormality | The solution for M7095-PLC timed out waiting for the host computer to transmit the weighing result can be resolved by checking the communication settings in the PLC and making sure they are correct, resetting the PLC and |
KM-ASSYM1-03 | 6 | M7007 | Alarm: pressing position blocked_sensor double lights | Organizational Abnormality | There are several possible causes for this error, including a malfunctioning light sensor or an issue with the camera. However, the most common solution is to clean the affected area thoroughly and try again. If the problem persists, contact the manufacturer or |
KM-ASSYM1-03 | 8 | M7009 | Alarm: pad pushes out cylinder 1_moving position alarm | Organizational Abnormality | The solution for the "pad pushes out cylinder 1_moving position alarm" error would likely involve checking the wiring and making sure that the pad and cylinder are properly aligned. It is recommended to contact a professional mechanic if |
KM-ASSYM1-03 | 32 | M7044 | Alarm: During initialization, the assembly line materials were not cleared. | Abnormal personnel operation | To resolve the "Alarm: During initialization, the assembly line materials were not cleared." error, ensure that all materials are properly placed and cleared from the assembly line before beginning operations. This can prevent any potential issues during the initial setup of the production |
KM-ASSYM1-03 | 33 | M7045 | Alarm: initial startup, there is material in the assembly line | Abnormal personnel operation | To fix the error described as Alarm: initial startup, there is material in the assembly line, you'll need to identify the source of the material and clear it from the assembly line. This may require adjusting your manufacturing processes or stopping production |
KM-ASSYM1-05 | 1 | M7000 | M7000-The glue bucket is about to be used up, please prepare to fill the glue bucket | Abnormal personnel operation | The solution to the M7000 error message "The glue bucket is about to be used up, please prepare to fill the glue bucket" is to refill the empty glue bucket before it runs out of glue. This |
KM-ASSYM1-05 | 2 | M7001 | M7001-Start detecting that there is material in the work area, please select the work area status | Abnormal personnel operation | The solution for the error "M7001-Start detecting that there is material in the work area, please select the work area status?" is to ensure that the appropriate work area is selected before starting the processing by either re-routing |
KM-ASSYM1-05 | 7 | M7006 | M7006-1 point detection failed | Visual abnormality | The solution for the M7006-1 error "point detection failed" cannot be provided without additional information about the underlying cause. This error occurs when the device fails to detect a point or location. It could be due to various reasons such |
KM-ASSYM1-05 | 8 | M7007 | M7007-2 point detection failed | Visual abnormality | The solution for the M7007-2 point detection failed error typically involves resetting the camera or device, updating driver software, or contacting technical support for further assistance. |
KM-ASSYM1-05 | 9 | M7008 | M7008-3 point detection failed | Visual abnormality | The M7008-3 point detection failed error is typically caused by issues with the camera or computer hardware, improper software installation or settings, or insufficient light conditions. The solution may include checking for hardware malfunctions, updating software and |
KM-ASSYM1-05 | 10 | M7009 | M7009-4 point detection failed | Visual abnormality | The solution for the error "M7009-4 point detection failed" typically involves checking the camera's settings, performing a calibration, and updating any necessary software. If the issue persists, it may require technical support from the |
KM-ASSYM1-05 | 11 | M7010 | M7010-5 point detection failed | Visual abnormality | The M7010-5 point detection failed error typically occurs when the device's camera is unable to detect points due to poor lighting conditions, camera focus, or hardware problems. To resolve this issue, try cleaning the camera lens, adjust |
KM-ASSYM1-05 | 12 | M7011 | M7011-6 point detection failed | Visual abnormality | The M7011-6 error occurs when the camera is unable to accurately detect points in the field of view. Possible causes of this error include poor lighting conditions, camera shake or movement, incorrect lens settings, or a dirty or damaged |
KM-ASSYM1-05 | 13 | M7012 | M7012-7 point detection failed | Visual abnormality | M7012-7 error occurs when the camera cannot detect any point on an object during image processing. This can be due to poor image quality or lighting conditions. A possible solution is to adjust the camera parameters, such as focus or bright |
KM-ASSYM1-05 | 14 | M7013 | M7013-8 point detection failed | Visual abnormality | M7013-8 point detection failed error can occur in AutoCAD when the program is unable to detect points accurately. One potential solution is to increase the accuracy of the point detection settings or to use a different type of point detection algorithm |
KM-ASSYM1-05 | 15 | M7014 | M7014-9 point detection failed | Visual abnormality | The solution for error M7014-9 is to check the image quality, ensure the object is visible, and review the settings in the object detection algorithm. If necessary, you may need to adjust the object detection parameters, increase the object |
KM-ASSYM1-05 | 16 | M7015 | M7015-10 point detection failed | Visual abnormality | The solution for M7015-10 error, point detection failed, may refer to re-enabling point detection in the camera's settings, correcting the camera's focus and resolution, or updating the camera driver. In |
KM-ASSYM1-05 | 17 | M7016 | M7016-Emergency stop&&safety door is open, please check the safety door and emergency stop switch (X30) | Abnormal personnel operation | The solution for the M7016-Emergency stop&& safety door is open error is to check the safety door and emergency stop switch (X30). Make sure that the safety door is closed and the emergency stop switch is turned |
KM-ASSYM1-05 | 18 | M7017 | M7017-The device model setting has not been set, please set the device model | Abnormal personnel operation | To fix the M7017 error, you need to set the device model on your Amazon App Store account. This can be done by following the steps in the Amazon Developer Console: |
KM-ASSYM1-05 | 19 | M7018 | M7018-The automatic process is not reset before starting, please press the reset button first | Abnormal personnel operation | The solution to the M7018 error is to press the reset button first before attempting to start the automatic process. Once the reset is complete, the process should restart without any issues. |
KM-ASSYM1-05 | 20 | M7019 | M7019-The device has not returned to the origin, please execute the device to return to the origin first | Abnormal personnel operation | The solution to the M7019 error is to first execute the device to return to its origin before attempting any further actions. This error occurs when a device is not properly synchronized with its origin, and it requires the device to be returned to |
KM-ASSYM1-05 | 38 | M7037 | M7037-The discharging operation of the rear buffer conveyor belt times out, please check whether there is any jamming between the upper and lower reaches of the machine | Organizational Abnormality | M7037 error occurs when the discharging operation of the rear buffer conveyor belt times out and there is jamming between the upper and lower reaches of the machine. The solution is to clear any jamming in the machine, ensuring |
KM-ASSYM1-05 | 41 | M7040 | M7040-The right blocking cylinder in the work area rises abnormally (X42), please check whether the cylinder is stuck when rising | Organizational Abnormality | The solution to the M7040-The right blocking cylinder in the work area rises abnormally (X42) error is to check if the cylinder is stuck when rising. If the cylinder is stuck, it |
KM-ASSYM1-05 | 44 | M7043 | M7043-The lifting cylinder in the work area is abnormally descending (X45), please check whether the cylinder is stuck when descending | Organizational Abnormality | The solution for the M7043 error is to check the lifting cylinder for any abnormalities and ensure that it is functioning properly. This may involve troubleshooting or disassembling and reassembling the cylinder depending on |
KM-ASSYM1-05 | 51 | M7050 | M7050-The cylinder of the right glue cylinder in the slide area is rising abnormally (X55), please check whether the cylinder is stuck when rising | Organizational Abnormality | The M7050 error indicates that the right glue cylinder in the slide area is rising abnormally. To diagnose the issue, check whether the cylinder is stuck when rising. If it is, then the solution is to |
KM-ASSYM1-05 | 65 | M7064 | M7064-X-axis servo NO readly(X15)&ERROR, please check whether the X-axis servo driver is abnormal | Electronic control abnormality | The solution for the error M7064-X-axis servo NO ready(X15)&ERROR could involve several steps. First, unplug and plug in the X-axis servo driver to check if the issue is with |
KM-ASSYM1-05 | 68 | M7067 | M7067-X axis return to origin time has timed out, please check whether the slide table is abnormal or stuck | Electronic control abnormality | The error M7067 typically occurs when the X-axis slide table times out during its return to origin movement. This could be due to a malfunctioning actuator, a stuck slide table, or a problem with the home position |
KM-ASSYM1-05 | 71 | M7070 | M7070-Y axis rear limit is abnormal, far away from the origin end (X12), please check whether the slide table touches the limit | Electronic control abnormality | There are a few possible solutions to address the error M7070-Y axis rear limit is abnormal, far away from the origin end (X12) including:
1. Adjusting the slide table position to ensure |
KM-ASSYM1-05 | 74 | M7073 | M7073-The limit on the Z axis is abnormal, close to the origin end (X13), please check whether the slide table touches the limit | Electronic control abnormality | The solution to M7073 error that states the limit on the Z axis is abnormal, close to the origin end (X13) is to check whether the slide table touches the limit. This can be accomplished by physically inspecting |
KM-ASSYM1-05 | 90 | M7089 | M7089-The dispensing area detected by the upper camera is out of range | Visual abnormality | The solution for the M7089 error is to adjust the location and orientation of the upper camera to ensure it is within range of the dispensing area. If the camera cannot be moved, the error can also be resolved by adjusting the |
KM-ASSYM1-05 | 94 | M7093 | M7093-PLC timed out waiting for the host computer to send the scan code result | Machine communication abnormality | The solution for the error described as M7093-PLC timed out waiting for the host computer to send the scan code result is to ensure that the host computer is properly connected and responsive, and that the PLC settings are |
KM-ASSYM1-05 | 99 | M7098 | M7098-The current position of the PCB board exceeds the safe distance, please check whether the PC board is placed properly | Other exceptions | The solution to M7098 error is to check whether the PCB board is placed correctly and not exceeding the safe distance. The board should be centered properly and securely fastened to prevent any damage to the components or the board itself |
KM-ASSYM1-05 | 102 | M7101 | M7101-Please clean the scale pan and press the "Scale Pan Easy Clean Button" | Abnormal personnel operation | The solution for the error M7101 is to clean the scale pan using a cleaning tool provided by the scale manufacturer, and then to press the "Scale Pan Easy Clean Button" to reset the scale. If the problem persists, the |
KM-ASSYM1-05 | 113 | M7112 | M7112-Visual software model number is inconsistent with PLC model number | Visual abnormality | The solution to the M7112 error is to check that the visual software model number matches the PLC model number. If both numbers are correct, then the error may be caused by a mismatch between the cable connections, power supply, |
KM-ASSYM1-05 | 21 | M7020 | There is no code scanner in the work area of ??M7020-T surface, so self-inspection cannot be e done in the work area. Please put the undispensed plate in the front buffer to start | Abnormal personnel operation | The solution for this error is to move the undispensed plate from the work area to the front buffer so that it can be properly scanned for self-inspection. This will allow the code scanner to function properly and prevent further errors from |
KM-ASSYM1-05 | 33 | M7032 | M7032-The feeding operation of the front Buffer conveyor belt times out, please check whether there is any jamming between the upper and lower reaches of the machine | Organizational Abnormality | The error M7032 indicates that the feeding operation of the front buffer conveyor belt has timed out, which may be due to jamming between the upper and lower reaches of the machine. The solution to this issue is to check for |
KM-ASSYM1-05 | 34 | M7033 | M7033-The discharging operation of the front Buffer conveyor belt has timed out. Please check whether there is a jam between the front Buffer and the work area in the machine. | Organizational Abnormality | The solution for the M7033 error described as "Discharging operation of the front Buffer conveyor belt has timed out" is to check for any jam or obstruction between the front Buffer and the work area in the machine |
KM-ASSYM1-05 | 35 | M7034 | M7034-The feeding operation of the conveyor belt in the work area has timed out, please check whether the machine is jammed | Organizational Abnormality | The M7034 error message indicates that the conveyor belt feeding operation has timed out. To resolve this issue, first, check if the machine is jammed. Clear any blockages or jams from the conveyor belt. If |
KM-ASSYM1-05 | 36 | M7035 | M7035-The discharging operation of the conveyor belt in the work area has timed out, please check whether the machine is jammed | Organizational Abnormality | The solution for error M7035 is to manually check the conveyor belt for any jams or obstructions. If the belt is jammed, clear the obstruction and restart the machine. |
KM-ASSYM1-05 | 37 | M7036 | M7036-The feeding operation of the rear Buffer conveyor belt has timed out. Please check whether there is any jamming between the machine work area and the rear Buffer | Organizational Abnormality | The solution for the M7036 error is to check if there is any jamming between the machine work area and the rear Buffer, and to clear any blockages that are detected if possible. If the blockage cannot be cleared, then |
KM-ASSYM1-05 | 39 | M7038 | M7038-The left blocking cylinder in the work area rises abnormally (X40), please check whether the cylinder is stuck when rising | Organizational Abnormality | The solution for the M7038-The left blocking cylinder in the work area rises abnormally (X40) error is to check if the cylinder is stuck when rising. If the cylinder is stuck, you |
KM-ASSYM1-05 | 40 | M7039 | M7039-The left blocking cylinder in the work area is abnormally descending (X41), please check whether the cylinder is stuck when descending | Organizational Abnormality | The error message M7039-The left blocking cylinder in the work area is abnormally descending (X41), please check whether the cylinder is stuck when descending indicates that there is an issue on a cylinder |
KM-ASSYM1-05 | 42 | M7041 | M7041-The right blocking cylinder in the work area is abnormally descending (X43), please check whether the cylinder is stuck when descending | Organizational Abnormality | The M7041 error message indicates that the right blocking cylinder is descending abnormally and could be stuck. The solution is to check the cylinder for possible mechanical or electrical issues, such as worn or damaged seals, fault |
KM-ASSYM1-05 | 43 | M7042 | M7042-The jacking cylinder in the work area rises abnormally (X44), please check whether the cylinder is stuck when rising | Organizational Abnormality | The M7042 error occurs when the jacking cylinder in the work area rises abnormally. To resolve the error, check if the cylinder is stuck when it rises. If it is, try to release the cyl |
KM-ASSYM1-05 | 49 | M7048 | M7048-The cylinder of the left glue cylinder in the slide area is rising abnormally (X50), please check whether the cylinder is stuck when rising | Organizational Abnormality | If the left glue cylinder in the slide area is rising abnormally and showing error code M7048, it's possible that the cylinder is stuck. To resolve this issue, you can try applying a gentle pressure on |
KM-ASSYM1-05 | 50 | M7049 | M7049-The cylinder of the left glue cylinder in the slide area is abnormally descending (X54), please check whether the cylinder is stuck when descending | Organizational Abnormality | If you encounter the error M7049-The cylinder of the left glue cylinder in the slide area is abnormally descending (X54), it may indicate that the cylinder is stuck or has a problem with |
KM-ASSYM1-05 | 52 | M7051 | M7051-The cylinder of the right glue cylinder in the slide area is abnormally descending (X61), please check whether the cylinder is stuck when descending | Organizational Abnormality | The M7051 error message indicates that the cylinder in the slide area is descending abnormally. This issue could be caused by the cylinder becoming stuck while descending. To resolve this, check the cylinder for any block |
KM-ASSYM1-05 | 53 | M7052 | M7052-The dispensing cylinder cylinder does not sense the upper limit before the slide area moves, please press the reset button first | Organizational Abnormality | The solution to M7052 error is to press the reset button before moving the slide area. This will restart the machine and allow the dispensing cylinder to sense the upper limit before dispensing. This will prevent the error from occurring again |
KM-ASSYM1-05 | 54 | M7053 | M7053-The current glue amount is too much, please reduce it | Electronic control abnormality | Reduce the current glue amount by using less adhesive, replacing damaged parts, or adjusting the bonding process to ensure proper adhesion. In some cases, the use of a different type of adhesive or solvent may |
KM-ASSYM1-05 | 55 | M7054 | M7054-The current dispensing amount is too small, please increase | Electronic control abnormality | The error M7054 usually occurs when the dispensing amount is less than the minimum amount required. To solve this error, you need to increase the dispensing amount by adjusting the settings on your printer or using a different ink cartr |
KM-ASSYM1-05 | 66 | M7065 | M7065-The right limit of the X-axis is abnormal, close to the origin end (X7), please check whether the slide table touches the limit | Electronic control abnormality | The solution for the M7065 error is to check if the slide table is touching the limit at the origin end (X7) and increase the left limit value if necessary to prevent the issue. |
KM-ASSYM1-05 | 67 | M7066 | M7066-X axis left limit is abnormal, far away from the origin end (X10), please check whether the slide table touches the limit | Electronic control abnormality | The solution for M7066-X axis left limit error is to verify whether the slide table is touching the limit. If it is touching the limit, adjust the limit switches to stop the slide table from touching. If it is not |
KM-ASSYM1-05 | 69 | M7068 | M7068-Y-axis servo NO readly(X16)&ERROR, please check whether the X-axis servo driver is abnormal | Electronic control abnormality | The solution for the error described as M7068-Y-axis servo NO readly(X16) &ERROR is to confirm whether the X-axis servo driver is functioning correctly. This can be done by using the |
KM-ASSYM1-05 | 70 | M7069 | M7069-Y axis front limit is abnormal, close to the origin end (X11), please check whether the slide table touches the limit | Electronic control abnormality | The solution for M7069-Y axis front limit is abnormal, close to the origin end (X11) is to check whether the slide table touches the limit. The problem could be caused by the slide table moving too far |
KM-ASSYM1-05 | 72 | M7071 | M7071-Y axis return to origin time has timed out, please check whether the slide table is abnormal or stuck | Electronic control abnormality | The M7071-Y axis return to origin time has timed out error indicates that the Y-axis slide table is not responding to commands. This can be due to a stuck or abnormal condition. To troubleshoot this issue |
KM-ASSYM1-05 | 73 | M7072 | M7072-Z-axis servo NO readly(X17)&ERROR, please check whether the Z-axis servo driver is abnormal | Electronic control abnormality | The error M7072-Z-axis servo NO readly(X17)&ERROR typically indicates an issue with the Z-axis servo driver circuitry. It is recommended to first check for wiring errors or loose connections |
KM-ASSYM1-05 | 75 | M7074 | M7074-Z axis lower limit abnormality, far away from the origin end (X14), please check whether the slide table touches the limit | Electronic control abnormality | The solution for the error M7074 due to the lower limit abnormality of the Z-axis, far away from the origin end (X14), is to ensure that the slide table does not touch the limit. This can |
KM-ASSYM1-05 | 76 | M7075 | M7075-Z axis return to origin time has timed out, please check whether the slide table is abnormal or stuck | Electronic control abnormality | To resolve the M7075 error where the Z axis return to origin has timed out, make sure to check the slide table abnormality or sticking condition. If it is normal, the problem may be with the encoder or the |
KM-ASSYM1-05 | 81 | M7080 | M7080-Camera acquisition failed | Visual abnormality | The M7080-Camera acquisition failed error occurs when the camera is unable to acquire a clear image due to poor lighting conditions, distortion in the lens, or incorrect settings. To resolve this issue, first reset the camera and then check |
KM-ASSYM1-05 | 82 | M7081 | M7081-Timeout waiting for MARK point in place signal | Electronic control abnormality | This issue is often resolved by adjusting the default timeout value for the place signal waiting period in the configuration settings. You can either increase the timeout value or try implementing the "force Mark" button in the Mark dialog. If the issue persists, |
KM-ASSYM1-05 | 83 | M7082 | M7082-MARK point recognition failed | Visual abnormality | The solution for the M7082-MARK point recognition failed error is to reset the device's memory and perform the point recognition process again. If the issue persists, it may be necessary to consult the device's manual or contact |
KM-ASSYM1-05 | 84 | M7083 | M7083-CCD timed out waiting for PLC completion signal (please check D720=1) | Electronic control abnormality | The solution for the M7083-CCD timed out waiting for PLC completion signal error is to check that the D720=1 parameter is set correctly in the communication configuration of the PLC. If the parameter is |
KM-ASSYM1-05 | 85 | M7084 | M7084-Scan code NG | Electronic control abnormality | The M7084-Scan code NG error often indicates a connectivity issue between the scanner and the computer or printer. A possible solution is to check the connections, restart the devices, and update device drivers. If the issue pers |
KM-ASSYM1-05 | 86 | M7085 | M7085-TE reply card station Fail | Kazam exception | The solution for the error described as M7085-TE may vary depending on the specific issue and configuration of the system. It could involve resetting or updating the reply card station, checking for communication issues, or consulting the system documentation for |
KM-ASSYM1-05 | 87 | M7086 | M7086-Scan code OK and receive TE Read signal timeout | Kazam exception | This error typically occurs when there is no data available on the USB port. It could be due to a problem with the computer's USB interface or a malfunctioning printer. To resolve the issue, you may need to try restarting your computer |